British Columbia Fire Watch Course 2026
This course is for security guards in British Columbia who are posted on a fire watch while a fire alarm or sprinkler system is out of service, or during hot work. It covers the BC Fire Code and Fire Safety Act, local rules from Vancouver and Chilliwack, the fire watch log, and hot work.
Kort svar
Den här gratiskursen har lektioner på cirka 20 minuter och ett prov med 25 frågor. Med minst 80 % kan du ladda ner ett kursintyg (privat, inte ackrediterat). Kontrollerad mot officiella källor den 12 oktober 2026.
Det här lär du dig
- Name the BC fire laws and who enforces them
- Explain when the Fire Code calls for alternative measures such as a fire watch
- Apply local fire watch rules from BC fire departments
- Keep a fire watch log that meets a BC fire department's order
- Follow the minimum hot work fire watch rules in the BC Fire Code text
Få minst 80 % för att ladda ner ditt certifikat.
-
Fråga 1 av 25
Visa svar
Svar: D. The BC Fire Code 2024
The BC Fire Code 2024 is the current edition, administered and enforced by the Office of the Fire Commissioner.
-
Fråga 2 av 25
Visa svar
Svar: A. March 8, 2024
The Ministerial Order adopting the BC Fire Code 2024 took effect on March 8, 2024.
-
Fråga 3 av 25
Visa svar
Svar: C. The National Fire Code 2020
The order adopts Divisions A to C of the National Fire Code of Canada 2020 as the BC Fire Code, with BC amendments.
-
Fråga 4 av 25
Visa svar
Svar: C. The Office of the Fire Commissioner
The province says the Office of the Fire Commissioner is responsible for administering and enforcing the BC Fire Code.
-
Fråga 5 av 25
Visa svar
Svar: B. The Fire Safety Act
The province says the Fire Safety Act replaced the Fire Services Act as of August 1, 2024.
-
Fråga 6 av 25
Visa svar
Svar: C. The local authority, like a council
The Act defines a fire inspector as an individual designated by a local authority under section 8.
-
Fråga 7 av 25
Visa svar
Svar: C. That no fire hazard exists there
Section 7 says an owner must ensure that no fire hazard exists on or in the owner's premises.
-
Fråga 8 av 25
Visa svar
Svar: B. Report it at once to the fire department
Section 22 says the occupier, or the owner if there is none, must immediately report the fire to a fire department or the fire commissioner when no fire department attended.
-
Fråga 9 av 25
Visa svar
Svar: B. Alternative measures must be taken
Article 6.1.1.4 of the 2018 BC Fire Code text says alternative measures shall be taken during a shutdown to maintain protection.
-
Fråga 10 av 25
Visa svar
Svar: B. Extra fire watch service
The note for sprinkler shutdowns lists emergency hose lines, portable extinguishers, extra fire watch service and temporary water connections.
-
Fråga 11 av 25
Visa svar
Svar: A. With the fire department
The note says alternative measures for a fire alarm shutdown should be worked out in cooperation with the fire department.
-
Fråga 12 av 25
Visa svar
Svar: A. Through its own Fire By-law
Vancouver's Fire By-law No. 14419 adopts the BC Fire Code with the city's own changes.
-
Fråga 13 av 25
Visa svar
Svar: D. If out over 4 hours in a row in 24 hours
Vancouver asks owners to call 3-1-1 (in business hours) when a system is out more than 4 continuous hours in a 24-hour period, and again when it is back.
-
Fråga 14 av 25
Visa svar
Svar: C. Every 60 minutes
The order sets a minimum of every 30 minutes in business hours and every 60 minutes at other times for non-residential buildings.
-
Fråga 15 av 25
Visa svar
Svar: C. When it goes out and when it returns
The order requires notice to the central station when the system goes out and when it is back in service.
-
Fråga 16 av 25
Visa svar
Svar: A. At the main entrance and other key points
The order must be posted at the main entrance, with copies at other main access points, inside elevators and stairs, and at every tenancy.
-
Fråga 17 av 25
Visa svar
Svar: B. Names and locations of those needing help
The order asks whether anyone with a disability needs help and says to record their names and locations in the log.
-
Fråga 18 av 25
Visa svar
Svar: B. At least every 15 minutes
Chilliwack requires patrols at least every 15 minutes during sleeping hours, 9 pm to 8 am.
-
Fråga 19 av 25
Visa svar
Svar: A. A dedicated person who only looks for fires
Chilliwack says a fire watch is a dedicated person on site whose sole duty is to actively look for fires.
-
Fråga 20 av 25
Visa svar
Svar: A. At entrances, exits and elevators
Chilliwack asks for signs at all entrances, exits and elevators on each floor stating that a fire watch is in effect and its expected duration.
-
Fråga 21 av 25
Visa svar
Svar: B. An ASTTBC fire protection technician
Chilliwack says the owner should contact a qualified ASTTBC fire protection technician, who should notify the fire department.
-
Fråga 22 av 25
Visa svar
Svar: D. Not a substitute for repairing it
Chilliwack states that temporary measures such as a fire watch are not a substitute for repairing the system.
-
Fråga 23 av 25
Visa svar
Svar: D. At least 60 minutes
Article 5.2.3.1 of the 2018 BC Fire Code text requires a continuous fire watch for not less than 60 minutes after hot work is completed.
-
Fråga 24 av 25
Visa svar
Svar: D. 4 hours after the work
Article 5.2.3.1 of the 2018 BC Fire Code text requires an inspection 4 hours after completion, or a more thorough one when the fire watch ends.
-
Fråga 25 av 25
Visa svar
Svar: C. In the building
Article 2.8.2.5 of the 2018 BC Fire Code text says the fire safety plan must be kept in the building for reference by the fire department.
Tangentbord: 1–4 för att svara, Enter för nästa fråga.
Bra att veta före provet
- The BC Fire Code 2024 adopts the National Fire Code of Canada 2020 with BC changes and took effect on March 8, 2024.
- The Office of the Fire Commissioner administers and enforces the BC Fire Code.
- BC's Fire Safety Act replaced the Fire Services Act on August 1, 2024.
- Vancouver asks owners to call 3-1-1 if a fire protection system is out for more than 4 continuous hours in 24 hours.
- Chilliwack requires fire watch patrols at least every 15 minutes from 9 pm to 8 am in buildings where people sleep.
Vanliga frågor
Who enforces fire rules in British Columbia?
The Office of the Fire Commissioner administers and enforces the BC Fire Code. Local governments designate fire inspectors under the Fire Safety Act, and Vancouver uses its own Fire By-law.
How often do I patrol on a fire watch in BC?
It depends on the local fire department. Vancouver and Chilliwack both ask for rounds every 15 minutes overnight in buildings where people sleep, and every 30 to 60 minutes in other cases.
Do I need to call the fire department when an alarm goes out?
Follow your local rules. In Vancouver, owners call 3-1-1 if a system is out more than 4 continuous hours in 24 hours. In Chilliwack, the fire protection technician notifies the fire department.
How long does a hot work fire watch last in BC?
The hot work section of the 2018 BC Fire Code text requires a continuous fire watch for at least 60 minutes after the work ends, and an inspection 4 hours after. Check the current code and your hot work permit.
Är intyget ackrediterat eller officiellt erkänt?
Nej. Det är ett privat kursintyg, bara för dina kunskaper. Det är inte erkänt, ackrediterat eller godkänt av någon myndighet, tillståndsmyndighet, tillsynsmyndighet eller utbildningsinstitution, och det ersätter inte någon licens, certifiering eller utbildning som krävs enligt lag.
Källor
- Government of BC: BC Fire Code
- Ministerial Order adopting the BC Fire Code 2024
- Fire Safety Act, SBC 2016, c. 19 (BC Laws)
- BC Fire Code (2018 text), Division B, Section 6.1 and Part 6 notes
- BC Fire Code (2018 text), Division B, Section 5.2 Hot Work
- City of Vancouver: Fire watch order
- City of Chilliwack: Fire watch
- City of Chilliwack: Fire protection equipment out of service