Fire Safety, First Aid and Evacuation Course (EU): Alarms, escape routes and safety signs

Quiz thématique sans limite de temps : 19 questions sur Alarms, escape routes and safety signs, avec une explication après chaque réponse. Les questions et les réponses sont mélangées à chaque fois.

  • Formation
  • Union européenne
  • 100 questions
  • Vérifié le 13 octobre 2026
  • Vérifié (faits) le 13 octobre 2026
Commencez par les leçonsFire Safety, First Aid and Evacuation Course (EU): Lessons : environ 150 minutes de lecture. Chaque question du test est traitée dans les leçons.

Quiz thématique 4 : Alarms, escape routes and safety signs

  1. Question 1 sur 19

    Under Directive 92/58/EEC, what kind of sound must the acoustic signal for evacuation make?
    Voir la réponse

    Réponse: D. A continuous sound

    Annex VII says the signal for evacuation must be continuous.

  2. Question 2 sur 19

    How loud must an acoustic safety signal be?
    Voir la réponse

    Réponse: B. Clearly louder than the background noise

    Acoustic signals must have a sound level considerably higher than the ambient noise, so people can hear them.

  3. Question 3 sur 19

    Where must emergency routes and exits lead?
    Voir la réponse

    Réponse: A. As directly as possible to the open air or a safe area

    Annex I point 4.1 of Directive 89/654/EEC says emergency routes and exits must lead as directly as possible to the open air or to a safe area.

  4. Question 4 sur 19

    Which way must emergency doors open?
    Voir la réponse

    Réponse: D. Outwards

    Annex I point 4.4 of the Workplace Directive says emergency doors must open outwards.

  5. Question 5 sur 19

    Which type of door is NOT allowed when it is specifically intended as an emergency exit?
    Voir la réponse

    Réponse: C. A sliding or revolving door

    Annex I point 4.4 says sliding or revolving doors are not permitted if they are specifically intended as emergency exits.

  6. Question 6 sur 19

    A manager locks an emergency exit at night to stop theft while staff are still working. What does the Workplace Directive say?
    Voir la réponse

    Réponse: B. Emergency doors must not be locked

    Annex I point 4.6 says emergency doors must not be locked.

  7. Question 7 sur 19

    Pallets of stock are stored in the corridor leading to a fire exit. What is wrong?
    Voir la réponse

    Réponse: A. Routes and doors to exits must be free from obstruction

    Annex I point 4.6 says emergency routes and exits, and the routes and doors leading to them, must be free from obstruction so they can be used at any time.

  8. Question 8 sur 19

    Emergency routes that need lighting must have what, in case the normal lighting fails?
    Voir la réponse

    Réponse: D. Emergency lighting of adequate intensity

    Annex I point 4.7 says emergency routes and exits needing lighting must have emergency lighting of adequate intensity.

  9. Question 9 sur 19

    What does the number, distribution and size of emergency routes and exits depend on?
    Voir la réponse

    Réponse: C. Its use, equipment and size, and the most people present

    Annex I point 4.3 says they depend on the use, equipment and dimensions of the workplace and the maximum number of persons present.

  10. Question 10 sur 19

    What does an emergency escape sign look like under Directive 92/58/EEC?
    Voir la réponse

    Réponse: C. A white pictogram on a green background

    Emergency escape and first-aid signs are rectangular or square, with a white pictogram on a green background.

  11. Question 11 sur 19

    What does the safety colour green mean under Directive 92/58/EEC?
    Voir la réponse

    Réponse: B. Emergency escape and first aid, or no danger

    Green is for emergency escape and first-aid signs (doors, exits, routes, equipment, facilities) and for a return to normal.

  12. Question 12 sur 19

    What does the safety colour red mean under Directive 92/58/EEC?
    Voir la réponse

    Réponse: A. Prohibition, danger alarm and fire-fighting equipment

    Red is used for prohibition signs, danger alarms (stop, evacuate) and fire-fighting equipment.

  13. Question 13 sur 19

    A round sign shows a white pictogram on a blue background. What kind of sign is it?
    Voir la réponse

    Réponse: D. A mandatory sign, telling you what you must do

    Mandatory signs are round, with a white pictogram on a blue background, for example to wear protective equipment.

  14. Question 14 sur 19

    What shape and colours does a warning sign have under Directive 92/58/EEC?
    Voir la réponse

    Réponse: A. A triangle with a black pictogram on a yellow background

    Warning signs are triangular, with a black pictogram on a yellow background and black edging.

  15. Question 15 sur 19

    A round prohibition sign covers 1,200 cm². Under Directive 92/58/EEC, at least how much of it must be red?
    Voir la réponse

    Réponse: B. 420 cm²

    The red part of a prohibition sign must take up at least 35% of its area: 35% of 1,200 cm² is 420 cm².

  16. Question 16 sur 19

    A green escape sign measures 30 cm by 15 cm. At least how much of its area must be green?
    Voir la réponse

    Réponse: B. 225 cm²

    The sign's area is 30 × 15 = 450 cm², and green must cover at least 50%, which is 225 cm².

  17. Question 17 sur 19

    Exit signs that need electricity to work must have what?
    Voir la réponse

    Réponse: B. A guaranteed emergency power supply

    Annex I of Directive 92/58/EEC says signs needing power must have a guaranteed emergency supply in case of a power cut.

  18. Question 18 sur 19

    There is a serious, imminent and unavoidable danger. What must the employer make possible for workers?
    Voir la réponse

    Réponse: C. To stop work and leave immediately for a place of safety

    Article 8(3)(b) of the Framework Directive says the employer must enable workers to stop work and/or leave immediately and go to a place of safety.

  19. Question 19 sur 19

    After everyone is out, why should you go to the assembly point and not just go home?
    Voir la réponse

    Réponse: A. So the people in charge can check that everyone is out

    Your site's emergency plan names an assembly point so that people can be counted and the emergency services told if anyone may still be inside.