PassEveryTest

Ontario Fire Watch Course 2026

This course is for security guards in Ontario who may be posted on a fire watch while a fire alarm or sprinkler system is out of service. It covers the Ontario Fire Code and who enforces it, what fire safety plans must say about shutdowns, and how Ontario fire departments describe fire watch rounds, logs and emergency steps.

  • 课程
  • 安大略省
  • 25道题
  • 核对于2026年10月12日

快速解答

这门免费课程包含约30分钟的课文和一套25道题的测试。得分达到80%或以上即可下载结业证书(私人颁发,未经认证)。 已于2026年10月12日根据官方资料核对。

从课文开始Ontario Fire Watch Course: Lessons:阅读时间约30分钟。测试中的每道题在课文中都有讲解。

你将学到什么

  • Name the Ontario Fire Code and the agencies that enforce it
  • Explain the owner's duties when a fire protection system is shut down
  • Find and use the shutdown section of an approved fire safety plan
  • Patrol and keep a fire watch log the way Ontario fire departments describe
  • Respond safely to fire and end the watch correctly

得分达到80%或以上即可下载证书。

  1. 第1题,共25题

    The Ontario Fire Code is a regulation made under which Act?
    显示答案

    答案: C. The Fire Protection and Prevention Act, 1997

    The Ontario Fire Code is a regulation under the Fire Protection and Prevention Act, 1997 (FPPA).

  2. 第2题,共25题

    What is the regulation number of the Ontario Fire Code?
    显示答案

    答案: C. O. Reg. 213/07

    The Fire Code is O. Reg. 213/07. O. Reg. 213/91 is the construction safety regulation, a common mix-up.

  3. 第3题,共25题

    Who carries out most local enforcement of the Ontario Fire Code?
    显示答案

    答案: C. Municipal fire departments

    Municipal fire departments do most local Fire Code enforcement through inspections, orders, tickets and charges.

  4. 第4题,共25题

    Which provincial office administers the Fire Protection and Prevention Act and the Fire Code and advises fire departments?
    显示答案

    答案: A. The Office of the Fire Marshal

    The Office of the Fire Marshal (OFM) administers the FPPA and Fire Code and supports municipal fire departments.

  5. 第5题,共25题

    Under the Ontario Fire Code, who is generally responsible for following the Code in a building?
    显示答案

    答案: A. The owner, unless the Code says otherwise

    Division A, Article 1.2.1.1 makes the owner responsible for compliance unless the Code states otherwise.

  6. 第6题,共25题

    In Windsor's fire watch duties, what must start when a fire alarm or sprinkler system goes off-line?
    显示答案

    答案: C. A fire watch, immediately

    Windsor says that if a fire alarm or sprinkler system is off-line for any reason, the owner must start a fire watch immediately.

  7. 第7题,共25题

    What must a fire safety plan include about shutdowns of fire protection systems, under clause 2.8.2.1(1)(h)?
    显示答案

    答案: B. Alternative measures to keep occupants safe

    Clause 2.8.2.1(1)(h) requires the fire safety plan to provide alternative measures for occupant safety during any shutdown.

  8. 第8题,共25题

    Under Division B, Article 1.1.1.1, what is needed when fire protection systems are tested, repaired or changed?
    显示答案

    答案: C. A procedure to notify the fire department and occupants

    Article 1.1.1.1 requires a notification procedure for the fire department and occupants during tests, repairs or alterations.

  9. 第9题,共25题

    Who reviews and approves a building's fire safety plan in Ontario?
    显示答案

    答案: A. The Chief Fire Official

    The Ontario Fire Code requires the Chief Fire Official of the local fire department to review and approve fire safety plans.

  10. 第10题,共25题

    Where must an approved fire safety plan be kept?
    显示答案

    答案: B. In the building, at an approved location

    Sentence 2.8.2.1(3) requires the plan to be kept in the building at an approved location.

  11. 第11题,共25题

    How often must a fire safety plan be reviewed under the Ontario Fire Code?
    显示答案

    答案: A. At least every 12 months

    Sentence 2.8.2.1(4) requires a review at least every 12 months, or more often to reflect changes.

  12. 第12题,共25题

    Where must copies of a building's emergency procedures be posted?
    显示答案

    答案: C. At least one copy on each floor

    Sentence 2.8.2.5(1) requires at least one copy of the emergency procedures to be posted on each floor area.

  13. 第13题,共25题

    When must supervisory staff be trained in fire emergency procedures?
    显示答案

    答案: C. Before they get any fire safety duties

    Sentence 2.8.1.2(1) says supervisory staff must be trained before they are given fire safety responsibilities.

  14. 第14题,共25题

    How often must supervisory staff fire drills be held in a high building in Ontario?
    显示答案

    答案: A. Every 3 months

    Article 2.8.3.2 sets drills at least every 12 months in general and every 3 months in high buildings.

  15. 第15题,共25题

    How often do Windsor's fire watch duties say the entire building must be toured?
    显示答案

    答案: C. Every hour

    Windsor requires a tour of the entire building every hour until the alarm and sprinkler systems are restored.

  16. 第16题,共25题

    Under Windsor's duties, what happens if a system stays off-line for more than one day?
    显示答案

    答案: C. The fire department gets a daily status call

    Windsor asks for daily status updates to the fire department when a system is off-line more than one day.

  17. 第17题,共25题

    How do Windsor's duties say occupants must be told that a fire watch is in place?
    显示答案

    答案: B. In writing, with signs posted in common areas

    Occupants must be told in writing, and signs in common areas must show which system is out and the evacuation steps.

  18. 第18题,共25题

    A building's fire alarm does not send a signal to the fire department. What must be posted near each manual pull station?
    显示答案

    答案: A. A lasting notice to call the fire department

    Sentence 2.8.2.5(3) requires a durable notice near each pull station telling occupants to call the fire department.

  19. 第19题,共25题

    What do Windsor's fire watch duties say about hot work where sprinkler protection is impaired?
    显示答案

    答案: C. It is not allowed unless approved precautions are in place

    Windsor prohibits hot work such as welding or cutting in areas with impaired sprinklers unless approved precautions are in place.

  20. 第20题,共25题

    Under the City of London's long-term care fire watch policy, how often are unprotected areas checked?
    显示答案

    答案: D. Once every hour

    London's policy has the fire watch person check all unprotected areas once every hour, 24 hours a day, until the system is restored.

  21. 第21题,共25题

    Under Windsor's fire watch duties, who may staff a fire watch?
    显示答案

    答案: A. Responsible occupants, employees or contracted guards

    Windsor says fire watch staff can be a responsible occupant, employee or contracted security guard, with at least one qualified person present whenever the building is occupied.

  22. 第22题,共25题

    After an evacuation, when may a fire watch guard go back into the building, under Windsor's duties?
    显示答案

    答案: A. Only with the fire department's permission

    Windsor's duties say not to re-enter the building without the fire department's permission.

  23. 第23题,共25题

    When may a fire watch be cancelled?
    显示答案

    答案: C. Only after the system is confirmed fully working

    The watch is cancelled only once the system is confirmed fully operational; then the monitoring company and fire department are told.

  24. 第24题,共25题

    How often must every portable fire extinguisher be inspected under the Ontario Fire Code?
    显示答案

    答案: B. Every month

    Article 6.2.7.2 requires a monthly inspection of all portable fire extinguishers.

  25. 第25题,共25题

    What should each entry in a fire watch log show, according to Windsor's duties?
    显示答案

    答案: D. The time of each round, signed or initialled

    Windsor asks staff to record each completed round on the log sheet with the time and to sign or initial each entry.

考前须知

  • The Ontario Fire Code (O. Reg. 213/07) is a regulation under the Fire Protection and Prevention Act, 1997, and municipal fire departments enforce it.
  • Under the Fire Code, the fire safety plan must include alternative measures for occupant safety during any shutdown of fire protection systems.
  • The Chief Fire Official reviews and approves fire safety plans, and the plan is reviewed at least every 12 months.
  • Windsor Fire & Rescue requires a fire watch immediately when an alarm or sprinkler system is off-line, with a tour of the entire building every hour.
  • If a system is off-line more than one day, Windsor asks for a status call to the fire department every day.

常见问题

Who enforces the Ontario Fire Code?

Municipal fire departments do most local enforcement. The Office of the Fire Marshal administers the Fire Protection and Prevention Act and the Fire Code and supports fire departments.

How often do I patrol on a fire watch in Ontario?

Your fire department and the building's fire safety plan set the schedule. Windsor, for example, requires a tour of the entire building every hour.

Does the Ontario Fire Code mention fire watches?

The Fire Code requires the fire safety plan to set out alternative measures during a shutdown of fire protection systems. Fire departments such as Windsor's describe a fire watch as the usual measure.

Who must be told when a fire alarm is out of service?

Under Windsor's duties, the fire department and any monitoring company are called, and occupants are told in writing. Follow your fire safety plan and your fire department's rules.

这份证书是否经过认证或获得官方认可?

不是。这是一份私人颁发的结业证书,仅用于知识学习。它未获得任何政府、执照发放机构、监管机构或教育机构的认可、认证或批准,也不能替代法律要求的任何执照、资格证书或培训。

资料来源

相关测试