Ontario Fire Watch Course 2026
This course is for security guards in Ontario who may be posted on a fire watch while a fire alarm or sprinkler system is out of service. It covers the Ontario Fire Code and who enforces it, what fire safety plans must say about shutdowns, and how Ontario fire departments describe fire watch rounds, logs and emergency steps.
Kort antwoord
Deze gratis cursus heeft ongeveer 30 minuten lessen en een toets van 25 vragen. Haal 80% of meer om een bewijs van deelname te downloaden (privé, niet geaccrediteerd). Gecontroleerd aan de hand van officiële bronnen op 12 oktober 2026.
Wat je leert
- Name the Ontario Fire Code and the agencies that enforce it
- Explain the owner's duties when a fire protection system is shut down
- Find and use the shutdown section of an approved fire safety plan
- Patrol and keep a fire watch log the way Ontario fire departments describe
- Respond safely to fire and end the watch correctly
Haal 80% of meer om je certificaat te downloaden.
-
Vraag 1 van 25
Toon antwoord
Antwoord: C. The Fire Protection and Prevention Act, 1997
The Ontario Fire Code is a regulation under the Fire Protection and Prevention Act, 1997 (FPPA).
-
Vraag 2 van 25
Toon antwoord
Antwoord: C. O. Reg. 213/07
The Fire Code is O. Reg. 213/07. O. Reg. 213/91 is the construction safety regulation, a common mix-up.
-
Vraag 3 van 25
Toon antwoord
Antwoord: C. Municipal fire departments
Municipal fire departments do most local Fire Code enforcement through inspections, orders, tickets and charges.
-
Vraag 4 van 25
Toon antwoord
Antwoord: A. The Office of the Fire Marshal
The Office of the Fire Marshal (OFM) administers the FPPA and Fire Code and supports municipal fire departments.
-
Vraag 5 van 25
Toon antwoord
Antwoord: A. The owner, unless the Code says otherwise
Division A, Article 1.2.1.1 makes the owner responsible for compliance unless the Code states otherwise.
-
Vraag 6 van 25
Toon antwoord
Antwoord: C. A fire watch, immediately
Windsor says that if a fire alarm or sprinkler system is off-line for any reason, the owner must start a fire watch immediately.
-
Vraag 7 van 25
Toon antwoord
Antwoord: B. Alternative measures to keep occupants safe
Clause 2.8.2.1(1)(h) requires the fire safety plan to provide alternative measures for occupant safety during any shutdown.
-
Vraag 8 van 25
Toon antwoord
Antwoord: C. A procedure to notify the fire department and occupants
Article 1.1.1.1 requires a notification procedure for the fire department and occupants during tests, repairs or alterations.
-
Vraag 9 van 25
Toon antwoord
Antwoord: A. The Chief Fire Official
The Ontario Fire Code requires the Chief Fire Official of the local fire department to review and approve fire safety plans.
-
Vraag 10 van 25
Toon antwoord
Antwoord: B. In the building, at an approved location
Sentence 2.8.2.1(3) requires the plan to be kept in the building at an approved location.
-
Vraag 11 van 25
Toon antwoord
Antwoord: A. At least every 12 months
Sentence 2.8.2.1(4) requires a review at least every 12 months, or more often to reflect changes.
-
Vraag 12 van 25
Toon antwoord
Antwoord: C. At least one copy on each floor
Sentence 2.8.2.5(1) requires at least one copy of the emergency procedures to be posted on each floor area.
-
Vraag 13 van 25
Toon antwoord
Antwoord: C. Before they get any fire safety duties
Sentence 2.8.1.2(1) says supervisory staff must be trained before they are given fire safety responsibilities.
-
Vraag 14 van 25
Toon antwoord
Antwoord: A. Every 3 months
Article 2.8.3.2 sets drills at least every 12 months in general and every 3 months in high buildings.
-
Vraag 15 van 25
Toon antwoord
Antwoord: C. Every hour
Windsor requires a tour of the entire building every hour until the alarm and sprinkler systems are restored.
-
Vraag 16 van 25
Toon antwoord
Antwoord: C. The fire department gets a daily status call
Windsor asks for daily status updates to the fire department when a system is off-line more than one day.
-
Vraag 17 van 25
Toon antwoord
Antwoord: B. In writing, with signs posted in common areas
Occupants must be told in writing, and signs in common areas must show which system is out and the evacuation steps.
-
Vraag 18 van 25
Toon antwoord
Antwoord: A. A lasting notice to call the fire department
Sentence 2.8.2.5(3) requires a durable notice near each pull station telling occupants to call the fire department.
-
Vraag 19 van 25
Toon antwoord
Antwoord: C. It is not allowed unless approved precautions are in place
Windsor prohibits hot work such as welding or cutting in areas with impaired sprinklers unless approved precautions are in place.
-
Vraag 20 van 25
Toon antwoord
Antwoord: D. Once every hour
London's policy has the fire watch person check all unprotected areas once every hour, 24 hours a day, until the system is restored.
-
Vraag 21 van 25
Toon antwoord
Antwoord: A. Responsible occupants, employees or contracted guards
Windsor says fire watch staff can be a responsible occupant, employee or contracted security guard, with at least one qualified person present whenever the building is occupied.
-
Vraag 22 van 25
Toon antwoord
Antwoord: A. Only with the fire department's permission
Windsor's duties say not to re-enter the building without the fire department's permission.
-
Vraag 23 van 25
Toon antwoord
Antwoord: C. Only after the system is confirmed fully working
The watch is cancelled only once the system is confirmed fully operational; then the monitoring company and fire department are told.
-
Vraag 24 van 25
Toon antwoord
Antwoord: B. Every month
Article 6.2.7.2 requires a monthly inspection of all portable fire extinguishers.
-
Vraag 25 van 25
Toon antwoord
Antwoord: D. The time of each round, signed or initialled
Windsor asks staff to record each completed round on the log sheet with the time and to sign or initial each entry.
Toetsenbord: 1–4 om te antwoorden, Enter voor de volgende vraag.
Wat je moet weten voor het examen
- The Ontario Fire Code (O. Reg. 213/07) is a regulation under the Fire Protection and Prevention Act, 1997, and municipal fire departments enforce it.
- Under the Fire Code, the fire safety plan must include alternative measures for occupant safety during any shutdown of fire protection systems.
- The Chief Fire Official reviews and approves fire safety plans, and the plan is reviewed at least every 12 months.
- Windsor Fire & Rescue requires a fire watch immediately when an alarm or sprinkler system is off-line, with a tour of the entire building every hour.
- If a system is off-line more than one day, Windsor asks for a status call to the fire department every day.
Veelgestelde vragen
Who enforces the Ontario Fire Code?
Municipal fire departments do most local enforcement. The Office of the Fire Marshal administers the Fire Protection and Prevention Act and the Fire Code and supports fire departments.
How often do I patrol on a fire watch in Ontario?
Your fire department and the building's fire safety plan set the schedule. Windsor, for example, requires a tour of the entire building every hour.
Does the Ontario Fire Code mention fire watches?
The Fire Code requires the fire safety plan to set out alternative measures during a shutdown of fire protection systems. Fire departments such as Windsor's describe a fire watch as the usual measure.
Who must be told when a fire alarm is out of service?
Under Windsor's duties, the fire department and any monitoring company are called, and occupants are told in writing. Follow your fire safety plan and your fire department's rules.
Is het certificaat geaccrediteerd of officieel erkend?
Nee. Het is een privé bewijs van deelname, alleen voor je kennis. Het is niet erkend, geaccrediteerd of goedgekeurd door een overheid, vergunningsinstantie, toezichthouder of onderwijsinstelling, en het vervangt geen wettelijk verplichte vergunning, certificering of opleiding.
Bronnen
- Office of the Fire Marshal (Ontario.ca)
- Fire safety legislation and Ontario's Fire Code (Ontario.ca)
- O. Reg. 213/07: Fire Code (e-Laws)
- Windsor Fire & Rescue: Ontario Fire Code information for building owners
- Windsor Fire & Rescue: Fire watch duties
- Windsor Fire & Rescue: Fire safety plan templates
- City of London: Fire watch policy EMP03-009