Lockout/Tagout Awareness Course 2026
This course is for workers and security guards in Canada who work near machines that are locked out for repair or cleaning. It covers hazardous energy, locks and tags, the lockout steps and the rules for removing locks. It is background knowledge only: your employer must train you on its own written procedure before you lock out any equipment.
Kort svar
Den här gratiskursen har lektioner på cirka 25 minuter och ett prov med 25 frågor. Med minst 80 % kan du ladda ner ett kursintyg (privat, inte ackrediterat). Kontrollerad mot officiella källor den 13 oktober 2026.
Det här lär du dig
- Describe the main types of hazardous energy, including stored energy
- Tell an energy-isolating device apart from a control switch
- List the steps of a lockout in the right order
- Explain the rules for personal locks, keys and tags
- Explain who may remove a lock and what happens if that worker is absent
- Respond correctly when you find a lockout on patrol
Få minst 80 % för att ladda ner ditt certifikat.
-
Fråga 1 av 25
Visa svar
Svar: B. To stop a machine from being started or moving while someone works on it
Lockout holds an energy-isolating device in the safe position so equipment cannot be energized while people work on it.
-
Fråga 2 av 25
Visa svar
Svar: C. CSA Z460
CSA Z460, Control of hazardous energy — Lockout and other methods, sets out how to manage hazardous energy from machines and equipment.
-
Fråga 3 av 25
Visa svar
Svar: C. Gravitational energy
CCOHS says an overhead roll-up door has gravitational potential energy, so a raised door can drop if it is not blocked.
-
Fråga 4 av 25
Visa svar
Svar: A. Residual or stored energy
Energy left in a system after the supply is shut off, such as pressure in a line, is residual or stored energy. It must be released or blocked.
-
Fråga 5 av 25
Visa svar
Svar: A. A circuit breaker
Disconnect switches, circuit breakers, line valves and blocks isolate energy. Push buttons and selector switches are control switches, not isolating devices.
-
Fråga 6 av 25
Visa svar
Svar: D. A control switch does not isolate the energy source
Push buttons and other control circuit switches are not energy-isolating devices, so they do not make the machine safe to work on.
-
Fråga 7 av 25
Visa svar
Svar: A. The reason, the date and time, and who applied it
A tag states why the lockout is in place, when it was applied and the name of the authorized person who applied it.
-
Fråga 8 av 25
Visa svar
Svar: A. Three locks, one for each worker
Each person must place their own lock on the system, so the number of locks matches the number of workers.
-
Fråga 9 av 25
Visa svar
Svar: B. One key, with no master key
CCOHS says each lock has one key and master keys are not allowed, so only the person who placed it can open it.
-
Fråga 10 av 25
Visa svar
Svar: B. Keep immediate control of it
Section 10.7 of BC's OHS Regulation says workers must keep immediate control of the keys to their personal locks for the whole job.
-
Fråga 11 av 25
Visa svar
Svar: A. The worker who installed it
Section 10.8 of BC's OHS Regulation says a personal lock must only be removed by the worker who installed it.
-
Fråga 12 av 25
Visa svar
Svar: D. Make every reasonable effort to contact that worker
Section 10.8 says the supervisor or manager must try hard to contact the worker who installed the lock and make sure the equipment can be run safely.
-
Fråga 13 av 25
Visa svar
Svar: C. At the start of their next shift
Section 10.8(3) of BC's OHS Regulation says the worker must be told at the start of their next shift if their lock was removed.
-
Fråga 14 av 25
Visa svar
Svar: A. Prepare by identifying the equipment and energy sources
The first step is to prepare: identify the equipment, all its energy sources and the devices needed to isolate them.
-
Fråga 15 av 25
Visa svar
Svar: B. After the energy is isolated and stored energy is released
CCOHS lists the order as shut down, isolate, release stored energy, then apply locks and tags, then verify.
-
Fråga 16 av 25
Visa svar
Svar: D. To verify that the machine will not start
Verifying isolation proves the lockout works. BC's regulation requires workers to verify that all energy sources are locked out before work starts.
-
Fråga 17 av 25
Visa svar
Svar: A. Trying the start controls to confirm it will not run
A bump test is an attempt to activate the equipment after isolation to confirm it will not operate, as part of verifying isolation.
-
Fråga 18 av 25
Visa svar
Svar: B. Check the area and make sure everyone is clear
CCOHS says to inspect the area, confirm people are clear, put controls in neutral, remove devices and tell affected workers before re-energizing.
-
Fråga 19 av 25
Visa svar
Svar: A. When every worker's personal lock is off the box
In group control, the keys go in a lock box and each worker adds a personal lock. The keys cannot be removed until all personal locks are off.
-
Fråga 20 av 25
Visa svar
Svar: B. Part 15
Part 15 of Alberta's OHS Code, Managing the Control of Hazardous Energy, covers isolation, verifying isolation, personal locks and returning to operation.
-
Fråga 21 av 25
Visa svar
Svar: B. The energy-isolating devices must be locked out
Section 10.3 says no work may be done on shut-down machinery until, among other things, the energy-isolating devices are locked out.
-
Fråga 22 av 25
Visa svar
Svar: C. A trained person assigned to carry out lockout
CCOHS describes an authorized person as someone qualified through knowledge, training and experience who has been assigned to carry out hazardous energy control.
-
Fråga 23 av 25
Visa svar
Svar: A. Leave it in place and report it to your supervisor
Only the worker who installed a lock may remove it, under the site's procedure. A guard should never touch it and should report concerns.
-
Fråga 24 av 25
Visa svar
Svar: D. A tag warns people but cannot physically stop anyone
CCOHS says tagout is always used when lockout is required. The lock is what holds the isolating device in the safe position; a tag only warns.
-
Fråga 25 av 25
Visa svar
Svar: B. The supervisor, as part of the employer's program
CCOHS says supervisors must ensure only trained people do lockout work, and employers must train workers on their roles.
Tangentbord: 1–4 för att svara, Enter för nästa fråga.
Bra att veta före provet
- CSA Z460, Control of hazardous energy — Lockout and other methods, is the Canadian standard for lockout.
- Push buttons and selector switches are not energy-isolating devices. Breakers, disconnects, line valves and blocks are.
- Each worker puts on their own lock. Each lock has one key, and master keys are not allowed.
- In BC, a worker must verify that all energy sources are locked out before starting work (OHS Regulation s. 10.6).
- In BC, a personal lock may only be removed by the worker who installed it, except under the s. 10.8 removal process.
Vanliga frågor
What is the difference between lockout and tagout?
Lockout puts a lock on an energy-isolating device so the machine cannot be turned on. Tagout adds a tag that says why, when and who. The tag is used with the lock, not instead of it.
Does this course let me lock out equipment at work?
No. It is background knowledge only. Your employer must train you on its hazardous energy program and the written procedure for each machine, and only trained, assigned workers may do lockout.
Can a supervisor remove a worker's lock?
Only under a special procedure. In BC, the supervisor must make every reasonable effort to contact the worker, make sure the equipment is safe, and the worker is told at the start of their next shift.
What should a security guard do if they see a lockout?
Leave the lock and tag alone, never operate the equipment, and report anything that looks damaged, tampered with or unsafe to a supervisor.
Är intyget ackrediterat eller officiellt erkänt?
Nej. Det är ett privat kursintyg, bara för dina kunskaper. Det är inte erkänt, ackrediterat eller godkänt av någon myndighet, tillståndsmyndighet, tillsynsmyndighet eller utbildningsinstitution, och det ersätter inte någon licens, certifiering eller utbildning som krävs enligt lag.
Källor
- CCOHS: Lockout/Tag out
- CCOHS: Hazardous energy control programs
- Standards Council of Canada: CSA Z460 Control of hazardous energy — Lockout and other methods
- WorkSafeBC: OHS Regulation Part 10, De-energization and Lockout
- Alberta OHS Code Part 15: Managing the Control of Hazardous Energy
- Government of Alberta: OHS Code Part 15 explanation guide