Quebec Fire Watch Course 2026
This course is for security guards in Quebec who are posted on a fire watch while a fire alarm or sprinkler system is out of service, or near hot work. It covers the Safety Code and city fire bylaws, building owners' duties, local alarm and sprinkler rules, and firefighters' powers under the Fire Safety Act.
Resposta rápida
Este curso gratuito tem cerca de 25 minutos de lições e um teste de 25 perguntas. Com 80% ou mais pode descarregar um certificado de conclusão (privado, não acreditado). Verificado com fontes oficiais em 12 de outubro de 2026.
O que vai aprender
- Name the codes and laws that set fire safety rules in Quebec
- Describe the fire safety duties of building owners under the Safety Code
- Apply local rules about resetting alarms and shutting off sprinklers
- Carry out and log fire watch rounds as your site and fire service require
- Respond to a fire and explain firefighters' powers under the Fire Safety Act
Obtenha 80% ou mais para descarregar o seu certificado.
-
Pergunta 1 de 25
Mostrar resposta
Resposta: A. The Fire Safety Act
The roles of the different actors in fire prevention, planning and firefighting are set out in the Fire Safety Act, chapter S-3.4.
-
Pergunta 2 de 25
Mostrar resposta
Resposta: A. The Régie du bâtiment du Québec (RBQ)
Section 31 of the Building Act says the Régie du bâtiment du Québec (RBQ) adopts a safety code. Chapter VIII – Building holds the fire safety rules for many existing buildings.
-
Pergunta 3 de 25
Mostrar resposta
Resposta: D. The National Fire Code of Canada 2020, with Quebec amendments
The RBQ says Chapter VIII consists of the National Fire Code of Canada 2020 with Quebec amendments, after a change on April 17, 2025.
-
Pergunta 4 de 25
Mostrar resposta
Resposta: D. March 18, 2013
The RBQ says Chapter VIII – Building has been in force since March 18, 2013, and was modified on April 17, 2025.
-
Pergunta 5 de 25
Mostrar resposta
Resposta: D. Yes, for buildings in its own territory
The RBQ says a municipality may adopt more stringent standards for buildings in its territory, so always check the local bylaw.
-
Pergunta 6 de 25
Mostrar resposta
Resposta: C. The National Fire Code of Canada 2010
The Montreal fire department says the by-law, adopted on January 24, 2012, was amended to conform to the National Fire Code – Canada 2010.
-
Pergunta 7 de 25
Mostrar resposta
Resposta: C. The municipality
Municipalities manage their fire safety service, which assesses risks, does prevention, fights fires and investigates their causes.
-
Pergunta 8 de 25
Mostrar resposta
Resposta: C. Sprinklers and fire alarm systems
The RBQ lists keeping sprinklers, fire alarms, door closers and emergency equipment in good and safe operating condition as an owner duty.
-
Pergunta 9 de 25
Mostrar resposta
Resposta: D. At least once a year
The RBQ says owners must make sure appropriate fire evacuation and rescue drills are held at least once a year.
-
Pergunta 10 de 25
Mostrar resposta
Resposta: D. In the building's register
The RBQ says inspection, verification, maintenance and repair records for fire safety systems must be kept in the building's register.
-
Pergunta 11 de 25
Mostrar resposta
Resposta: D. At least every 12 months
The modified code, reproduced in bylaws such as Beaconsfield's and Baie-D'Urfé's, says the plan is reviewed at intervals of at most 12 months.
-
Pergunta 12 de 25
Mostrar resposta
Resposta: C. After every fire drill
The modified code says the fire safety plan must be updated as needed and following every fire drill.
-
Pergunta 13 de 25
Mostrar resposta
Resposta: A. In all cases, as soon as the alert signal starts
A note in the modified code says that in all cases firefighters must be called at the onset of the alert signal.
-
Pergunta 14 de 25
Mostrar resposta
Resposta: C. The fire safety service has confirmed the cause
Saguenay's bylaw (article 49) forbids resetting or silencing the alarm until the cause is found, occupants are safe and the fire safety service has confirmed the cause.
-
Pergunta 15 de 25
Mostrar resposta
Resposta: C. The cause is found and the fire department is told
Saguenay's bylaw says no one may shut off a water-based system until the exact cause is found and the fire department is told the probable cause.
-
Pergunta 16 de 25
Mostrar resposta
Resposta: D. Two responsible persons reachable at all times
Saguenay's bylaw requires owners to post the names and numbers of two responsible persons, reachable at all times, on or near the alarm panel.
-
Pergunta 17 de 25
Mostrar resposta
Resposta: C. An alarm set off with no need, such as by a fault
Montreal's fire department defines an unfounded alarm as one triggered without need, such as from poor installation, malfunction, poor maintenance or wrong handling.
-
Pergunta 18 de 25
Mostrar resposta
Resposta: D. The site's arrangements and the local fire service
The texts reviewed set no single patrol frequency. Get the frequency in writing from your site and follow the local fire safety service.
-
Pergunta 19 de 25
Mostrar resposta
Resposta: A. Take the measures needed to protect people and property
Section 6 says the owner must, on receiving a formal notice, take the measures necessary to protect persons and property.
-
Pergunta 20 de 25
Mostrar resposta
Resposta: A. Three months
Section 5 says the hazard must be reported to the local municipality within three months of becoming subject to the regulation.
-
Pergunta 21 de 25
Mostrar resposta
Resposta: C. Require help from any person able to assist
Section 40 lets firefighters enter premises, prohibit access, order evacuation, order energy shut off and require the help of any capable person.
-
Pergunta 22 de 25
Mostrar resposta
Resposta: A. The fire chief or a qualified person they name
Section 43 makes the fire chief, or a qualified person the chief designates, responsible for finding the origin, probable causes and circumstances.
-
Pergunta 23 de 25
Mostrar resposta
Resposta: B. Hot work such as welding and cutting
The code (article 5.6.1.2 and its note, as reproduced in bylaws such as Beaconsfield's) lists hot work, including welding, cutting and hot roofing or tar work.
-
Pergunta 24 de 25
Mostrar resposta
Resposta: C. 9-1-1
For a fire, always call 9-1-1. Montreal lists 514 872-3800 for questions about its fire safety by-law, not for emergencies.
-
Pergunta 25 de 25
Mostrar resposta
Resposta: C. A store (mercantile occupancy) over 300 m²
The RBQ lists mercantile occupancies over 300 m² among the buildings covered, along with hotels, schools, hospitals and larger apartment buildings.
Teclado: 1–4 para responder, Enter para a pergunta seguinte.
O que saber antes do exame
- Chapter VIII – Building of Quebec's Safety Code now consists of the National Fire Code of Canada 2020 with Quebec amendments.
- Municipalities may adopt stricter fire rules. Montreal's fire safety by-law was made to conform to the 2010 National Fire Code.
- Owners must keep sprinklers, fire alarms, door closers and emergency equipment working, and hold evacuation drills at least once a year.
- Under section 6 of the Fire Safety Act, an owner who receives a formal notice must take the measures needed to protect people and property.
- Saguenay's bylaw forbids resetting a fire alarm until the cause is found and the fire safety service has confirmed it.
Perguntas frequentes
Which fire code applies in Quebec?
Chapter VIII – Building of the Safety Code, adopted by the RBQ, consists of the National Fire Code of Canada 2020 with Quebec amendments. Many cities also have fire prevention bylaws, often based on the 2010 code as modified for Quebec.
How often do I patrol on a fire watch in Quebec?
The code and the city bylaws in this course do not set one frequency for everyone. Get the frequency in writing from your site and follow the instructions of the local fire safety service.
Can I reset the fire alarm if it is a false alarm?
No. Bylaws such as Saguenay's forbid resetting or silencing an alarm until the cause is found and the fire safety service has confirmed it. Leave it to the fire service and the responsible persons.
What can firefighters ask me to do at a fire?
Under section 40 of the Fire Safety Act, firefighters may prohibit access, order an evacuation and require the help of any person able to assist. Follow their instructions.
O certificado é acreditado ou reconhecido oficialmente?
Não. É um certificado de conclusão privado, apenas para o seu conhecimento. Não é reconhecido, acreditado nem aprovado por nenhum governo, entidade licenciadora, regulador ou instituição de ensino e não substitui qualquer licença, certificação ou formação exigida por lei.
Fontes
- RBQ: Safety Code
- Building Act, B-1.1, section 31 (LégisQuébec)
- RBQ: Requirements of the National Fire Code
- Fire Safety Act, S-3.4 (LégisQuébec)
- Gouvernement du Québec: Rôles et responsabilités en sécurité incendie
- Ville de Saguenay: Bylaw VS-R-2025-6 on fire prevention
- Town of Baie-D'Urfé: By-law 1200-1 concerning fire safety
- Service de sécurité incendie de Montréal: By-law concerning fire safety