Quebec Fire Watch Course 2026

This course is for security guards in Quebec who are posted on a fire watch while a fire alarm or sprinkler system is out of service, or near hot work. It covers the Safety Code and city fire bylaws, building owners' duties, local alarm and sprinkler rules, and firefighters' powers under the Fire Safety Act.

  • Cursus
  • Quebec
  • 25 vragen
  • Gecontroleerd op 12 oktober 2026

Kort antwoord

Deze gratis cursus heeft ongeveer 25 minuten lessen en een toets van 25 vragen. Haal 80% of meer om een bewijs van deelname te downloaden (privé, niet geaccrediteerd). Gecontroleerd aan de hand van officiële bronnen op 12 oktober 2026.

Begin met de lessenQuebec Fire Watch Course: Lessons: ongeveer 25 minuten leestijd. Elke testvraag wordt in de lessen behandeld.

Wat je leert

  • Name the codes and laws that set fire safety rules in Quebec
  • Describe the fire safety duties of building owners under the Safety Code
  • Apply local rules about resetting alarms and shutting off sprinklers
  • Carry out and log fire watch rounds as your site and fire service require
  • Respond to a fire and explain firefighters' powers under the Fire Safety Act

Haal 80% of meer om je certificaat te downloaden.

  1. Vraag 1 van 25

    Which Quebec law sets out the roles of the province, municipalities and others in fire prevention and firefighting?
    Toon antwoord

    Antwoord: A. The Fire Safety Act

    The roles of the different actors in fire prevention, planning and firefighting are set out in the Fire Safety Act, chapter S-3.4.

  2. Vraag 2 van 25

    Which provincial body adopts Quebec's Safety Code, including Chapter VIII – Building?
    Toon antwoord

    Antwoord: A. The Régie du bâtiment du Québec (RBQ)

    Section 31 of the Building Act says the Régie du bâtiment du Québec (RBQ) adopts a safety code. Chapter VIII – Building holds the fire safety rules for many existing buildings.

  3. Vraag 3 van 25

    According to the RBQ, what does Chapter VIII – Building of the Safety Code now consist of?
    Toon antwoord

    Antwoord: D. The National Fire Code of Canada 2020, with Quebec amendments

    The RBQ says Chapter VIII consists of the National Fire Code of Canada 2020 with Quebec amendments, after a change on April 17, 2025.

  4. Vraag 4 van 25

    Since when has Chapter VIII – Building of Quebec's Safety Code been in force?
    Toon antwoord

    Antwoord: D. March 18, 2013

    The RBQ says Chapter VIII – Building has been in force since March 18, 2013, and was modified on April 17, 2025.

  5. Vraag 5 van 25

    Can a Quebec municipality adopt fire safety rules stricter than the Safety Code?
    Toon antwoord

    Antwoord: D. Yes, for buildings in its own territory

    The RBQ says a municipality may adopt more stringent standards for buildings in its territory, so always check the local bylaw.

  6. Vraag 6 van 25

    Montreal's By-law concerning fire safety, adopted in 2012, was made to conform to which code?
    Toon antwoord

    Antwoord: C. The National Fire Code of Canada 2010

    The Montreal fire department says the by-law, adopted on January 24, 2012, was amended to conform to the National Fire Code – Canada 2010.

  7. Vraag 7 van 25

    Who runs the fire safety service (service de sécurité incendie) in a Quebec community?
    Toon antwoord

    Antwoord: C. The municipality

    Municipalities manage their fire safety service, which assesses risks, does prevention, fights fires and investigates their causes.

  8. Vraag 8 van 25

    Under the Safety Code, which of these must a building owner keep in good and safe working order?
    Toon antwoord

    Antwoord: C. Sprinklers and fire alarm systems

    The RBQ lists keeping sprinklers, fire alarms, door closers and emergency equipment in good and safe operating condition as an owner duty.

  9. Vraag 9 van 25

    How often does the RBQ say fire evacuation drills must be held under the Safety Code?
    Toon antwoord

    Antwoord: D. At least once a year

    The RBQ says owners must make sure appropriate fire evacuation and rescue drills are held at least once a year.

  10. Vraag 10 van 25

    Where does the RBQ say inspection results and repair records for fire safety systems must be kept?
    Toon antwoord

    Antwoord: D. In the building's register

    The RBQ says inspection, verification, maintenance and repair records for fire safety systems must be kept in the building's register.

  11. Vraag 11 van 25

    Under Quebec's modified fire code, how often must a fire safety plan be reviewed?
    Toon antwoord

    Antwoord: D. At least every 12 months

    The modified code, reproduced in bylaws such as Beaconsfield's and Baie-D'Urfé's, says the plan is reviewed at intervals of at most 12 months.

  12. Vraag 12 van 25

    Besides when needed, when must a fire safety plan be updated under Quebec's modified fire code?
    Toon antwoord

    Antwoord: C. After every fire drill

    The modified code says the fire safety plan must be updated as needed and following every fire drill.

  13. Vraag 13 van 25

    According to Quebec's modified fire code, when must firefighters be called?
    Toon antwoord

    Antwoord: A. In all cases, as soon as the alert signal starts

    A note in the modified code says that in all cases firefighters must be called at the onset of the alert signal.

  14. Vraag 14 van 25

    Under Saguenay's fire prevention bylaw, which of these must happen before anyone resets or silences a fire alarm system?
    Toon antwoord

    Antwoord: C. The fire safety service has confirmed the cause

    Saguenay's bylaw (article 49) forbids resetting or silencing the alarm until the cause is found, occupants are safe and the fire safety service has confirmed the cause.

  15. Vraag 15 van 25

    Under Saguenay's bylaw, what must happen before a sprinkler (water-based) system is shut off after it activates?
    Toon antwoord

    Antwoord: C. The cause is found and the fire department is told

    Saguenay's bylaw says no one may shut off a water-based system until the exact cause is found and the fire department is told the probable cause.

  16. Vraag 16 van 25

    Under Saguenay's bylaw, whose names and phone numbers must be posted on or near the fire alarm panel?
    Toon antwoord

    Antwoord: D. Two responsible persons reachable at all times

    Saguenay's bylaw requires owners to post the names and numbers of two responsible persons, reachable at all times, on or near the alarm panel.

  17. Vraag 17 van 25

    Montreal has a bylaw on unfounded fire alarms. What is an unfounded alarm?
    Toon antwoord

    Antwoord: C. An alarm set off with no need, such as by a fault

    Montreal's fire department defines an unfounded alarm as one triggered without need, such as from poor installation, malfunction, poor maintenance or wrong handling.

  18. Vraag 18 van 25

    Under the fire code and the city bylaws in this course, what sets how often you patrol on a Quebec fire watch?
    Toon antwoord

    Antwoord: D. The site's arrangements and the local fire service

    The texts reviewed set no single patrol frequency. Get the frequency in writing from your site and follow the local fire safety service.

  19. Vraag 19 van 25

    Under section 6 of the Fire Safety Act, what must an owner do after a formal notice from the municipality about fire hazards that threaten public safety?
    Toon antwoord

    Antwoord: A. Take the measures needed to protect people and property

    Section 6 says the owner must, on receiving a formal notice, take the measures necessary to protect persons and property.

  20. Vraag 20 van 25

    Under section 5 of the Fire Safety Act, a person whose activities or property are a high or particular fire hazard must report it to the local municipality. How long do they have after becoming subject to the regulation?
    Toon antwoord

    Antwoord: A. Three months

    Section 5 says the hazard must be reported to the local municipality within three months of becoming subject to the regulation.

  21. Vraag 21 van 25

    Under section 40 of the Fire Safety Act, which of these may firefighters do during a fire?
    Toon antwoord

    Antwoord: C. Require help from any person able to assist

    Section 40 lets firefighters enter premises, prohibit access, order evacuation, order energy shut off and require the help of any capable person.

  22. Vraag 22 van 25

    Under section 43 of the Fire Safety Act, who must find the point of origin and probable causes of a fire?
    Toon antwoord

    Antwoord: A. The fire chief or a qualified person they name

    Section 43 makes the fire chief, or a qualified person the chief designates, responsible for finding the origin, probable causes and circumstances.

  23. Vraag 23 van 25

    Quebec's modified fire code requires a fire risk management program on construction sites for wood-frame residential buildings of more than four storeys. Which activity do its notes list for the program to cover?
    Toon antwoord

    Antwoord: B. Hot work such as welding and cutting

    The code (article 5.6.1.2 and its note, as reproduced in bylaws such as Beaconsfield's) lists hot work, including welding, cutting and hot roofing or tar work.

  24. Vraag 24 van 25

    You find smoke coming from a storage room during a fire watch in Montreal. Which number do you call?
    Toon antwoord

    Antwoord: C. 9-1-1

    For a fire, always call 9-1-1. Montreal lists 514 872-3800 for questions about its fire safety by-law, not for emergencies.

  25. Vraag 25 van 25

    Which of these buildings does the RBQ list as covered by the Buildings chapter of the Safety Code?
    Toon antwoord

    Antwoord: C. A store (mercantile occupancy) over 300 m²

    The RBQ lists mercantile occupancies over 300 m² among the buildings covered, along with hotels, schools, hospitals and larger apartment buildings.

Wat je moet weten voor het examen

  • Chapter VIII – Building of Quebec's Safety Code now consists of the National Fire Code of Canada 2020 with Quebec amendments.
  • Municipalities may adopt stricter fire rules. Montreal's fire safety by-law was made to conform to the 2010 National Fire Code.
  • Owners must keep sprinklers, fire alarms, door closers and emergency equipment working, and hold evacuation drills at least once a year.
  • Under section 6 of the Fire Safety Act, an owner who receives a formal notice must take the measures needed to protect people and property.
  • Saguenay's bylaw forbids resetting a fire alarm until the cause is found and the fire safety service has confirmed it.

Veelgestelde vragen

Which fire code applies in Quebec?

Chapter VIII – Building of the Safety Code, adopted by the RBQ, consists of the National Fire Code of Canada 2020 with Quebec amendments. Many cities also have fire prevention bylaws, often based on the 2010 code as modified for Quebec.

How often do I patrol on a fire watch in Quebec?

The code and the city bylaws in this course do not set one frequency for everyone. Get the frequency in writing from your site and follow the instructions of the local fire safety service.

Can I reset the fire alarm if it is a false alarm?

No. Bylaws such as Saguenay's forbid resetting or silencing an alarm until the cause is found and the fire safety service has confirmed it. Leave it to the fire service and the responsible persons.

What can firefighters ask me to do at a fire?

Under section 40 of the Fire Safety Act, firefighters may prohibit access, order an evacuation and require the help of any person able to assist. Follow their instructions.

Is het certificaat geaccrediteerd of officieel erkend?

Nee. Het is een privé bewijs van deelname, alleen voor je kennis. Het is niet erkend, geaccrediteerd of goedgekeurd door een overheid, vergunningsinstantie, toezichthouder of onderwijsinstelling, en het vervangt geen wettelijk verplichte vergunning, certificering of opleiding.

Bronnen

Gerelateerde examens