New Brunswick Fire Watch Course 2026
This course is for security guards in New Brunswick who may be posted on a fire watch while a fire alarm or sprinkler system is out of service, or during hot work. It covers the province's fire law, the Office of the Fire Marshal's fire watch technotes, the sign-off sheet and hot work rules.
Respuesta rápida
Este curso gratuito tiene unos 30 minutos de lecciones y un test de 25 preguntas. Con un 80 % o más puedes descargar un certificado de finalización (privado, no acreditado). Contrastado con fuentes oficiales el 12 de octubre de 2026.
Qué aprenderás
- Name the fire law, code and officials that apply in New Brunswick
- Explain when the Office of the Fire Marshal requires a fire watch
- Carry out hourly fire watch patrols with the right tools
- Keep an honest fire watch sign-off sheet
- Apply the province's hot work fire watch rules
- Respond safely if you find fire
Obtén un 80 % o más para descargar tu certificado.
-
Pregunta 1 de 25
Ver respuesta
Respuesta: C. National Fire Code of Canada 2020
Section 2(a) of Regulation 82-20 incorporates the National Fire Code of Canada 2020.
-
Pregunta 2 de 25
Ver respuesta
Respuesta: A. The Fire Prevention Act
Regulation 82-20 is made under New Brunswick's Fire Prevention Act.
-
Pregunta 3 de 25
Ver respuesta
Respuesta: A. May 1, 2025
Bulletin 2025-01 says the amended regulations, which adopt the 2020 National Fire Code and National Building Code, took effect May 1, 2025.
-
Pregunta 4 de 25
Ver respuesta
Respuesta: B. A fire chief or other fire department member
Section 6(1) of the Fire Prevention Act lets the fire marshal appoint the chief or another member of a fire department as a local assistant for that department's area.
-
Pregunta 5 de 25
Ver respuesta
Respuesta: A. Fire marshal, deputy, fire prevention officers or local assistants
Section 11 gives the fire marshal, deputy fire marshal, fire prevention officers and local assistants the power to inspect buildings at reasonable hours.
-
Pregunta 6 de 25
Ver respuesta
Respuesta: B. An offence, unless it is for maintenance and repairs
Section 23(a.1) makes it an offence to tamper with exits, extinguishers, sprinklers, detection or alarm systems without written authorization, except for maintenance and repairs.
-
Pregunta 7 de 25
Ver respuesta
Respuesta: D. Block an exit or the way to an exit
Section 23(a.2) makes it an offence to block an exit or an access to an exit, or remove an exit stair or fire escape, without written authorization.
-
Pregunta 8 de 25
Ver respuesta
Respuesta: D. An offence
Section 24(1) of the Fire Prevention Act says an owner or occupant who fails to comply with an order commits an offence.
-
Pregunta 9 de 25
Ver respuesta
Respuesta: B. A dedicated, 24 hour per day fire watch
Technote 2006-09R from the Office of the Fire Marshal requires a dedicated, 24 hour per day fire watch.
-
Pregunta 10 de 25
Ver respuesta
Respuesta: D. One or more persons whose only job is the fire watch
The technote says the fire watch is done by one or more persons whose only job function is providing the fire watch.
-
Pregunta 11 de 25
Ver respuesta
Respuesta: C. Hourly
Technote 2006-09R requires hourly patrols of the areas where the fire alarm or sprinkler system is not operational.
-
Pregunta 12 de 25
Ver respuesta
Respuesta: B. On a sign-off sheet with the time of each patrol
Each patrol is recorded on a sign-off sheet that shows the patrol was done and the time it was done.
-
Pregunta 13 de 25
Ver respuesta
Respuesta: A. A way to call 911 right away
The technote requires the fire watch to have a means to immediately contact 911 services.
-
Pregunta 14 de 25
Ver respuesta
Respuesta: D. The fire watch person or persons
The fire watch must have a means of contacting building occupants and is responsible for notifying them.
-
Pregunta 15 de 25
Ver respuesta
Respuesta: D. The construction fire safety plan
Technote 2006-09R says the fire watch must know the construction fire safety plan and understand their responsibilities in it.
-
Pregunta 16 de 25
Ver respuesta
Respuesta: D. Training in how to use a fire extinguisher
The technote requires the fire watch to be trained in the use of a fire extinguisher.
-
Pregunta 17 de 25
Ver respuesta
Respuesta: D. The contractor's staff are always in the affected area
Technote 2006-07R allows no fire watch during the contractor's work day only if the affected area is constantly occupied by their staff and any sprinkler system stays fully operational and monitored.
-
Pregunta 18 de 25
Ver respuesta
Respuesta: B. A dedicated fire watch
If the fire alarm system is not fully functional at the end of the contractor's work day, a dedicated fire watch is required.
-
Pregunta 19 de 25
Ver respuesta
Respuesta: A. The fire alarm works everywhere, including the work area
Technote 2006-08R requires the fire alarm system to be fully functional throughout the building, including the work area.
-
Pregunta 20 de 25
Ver respuesta
Respuesta: D. 60 minutes
Bulletin 2001-16 requires a fire watch during hot work and for 60 minutes after it is completed.
-
Pregunta 21 de 25
Ver respuesta
Respuesta: A. 4 hours after the work is finished
Bulletin 2001-16 requires an inspection of the hot work area 4 hours after the work is finished.
-
Pregunta 22 de 25
Ver respuesta
Respuesta: D. Within 15 m
Bulletin 2001-16 says combustible and flammable materials within 15 m must be protected from ignition.
-
Pregunta 23 de 25
Ver respuesta
Respuesta: B. At least one portable fire extinguisher
Bulletin 2001-16 requires at least one portable fire extinguisher in the hot work area.
-
Pregunta 24 de 25
Ver respuesta
Respuesta: B. Warn the occupants and call 911 from a safe place
With the alarm out of service, the fire watch must warn occupants and call 911 right away. Fight a fire only if it is small, you are trained and it is safe.
-
Pregunta 25 de 25
Ver respuesta
Respuesta: B. Record what really happened and the real time
The sign-off sheet must show when each patrol was really done. A false entry hides a gap in protection and can be used as evidence against you.
Teclado: 1–4 para responder, Intro para la siguiente pregunta.
Qué debes saber antes del examen
- New Brunswick adopts the National Fire Code of Canada 2020 through Regulation 82-20 under the Fire Prevention Act.
- The 2020 code amendments took effect in New Brunswick on May 1, 2025.
- A sprinkler or alarm system under modification needs a dedicated, 24 hour per day fire watch with hourly patrols.
- Tampering with alarms, sprinklers or extinguishers without written authorization is an offence under the Fire Prevention Act.
- A hot work fire watch lasts during the work and 60 minutes after, with an inspection 4 hours after.
Preguntas frecuentes
How often do I patrol on a fire watch in New Brunswick?
The Office of the Fire Marshal's Technote 2006-09R requires hourly patrols of the areas where the alarm or sprinklers are not working. Follow your post orders if they ask for more.
Can I do other duties during a fire watch?
No. Technote 2006-09R says the fire watch is done by people whose only job is the fire watch.
Who enforces the fire code in New Brunswick?
The fire marshal and the Office of the Fire Marshal, with deputy fire marshals, fire prevention officers and local assistants, who are often fire chiefs.
Is a fire watch needed while the contractor is working on the alarm?
Not always. Technote 2006-07R says no fire watch is needed during the contractor's work day if their staff are always in the affected area and the sprinklers stay fully working and monitored.
¿El certificado está acreditado o reconocido oficialmente?
No. Es un certificado de finalización privado, solo para tus conocimientos. No está reconocido, acreditado ni aprobado por ningún gobierno, organismo de licencias, regulador ni institución educativa, y no sustituye ninguna licencia, certificación ni formación exigida por la ley.
Fuentes
- Fire Prevention Act, c. F-13
- Fire Prevention and Inspection Regulation, N.B. Reg. 82-20
- Office of the Fire Marshal: Bulletin 2025-01, 2020 code adoption
- Office of the Fire Marshal: Fire Technote 2006-09R, Fire watch
- Office of the Fire Marshal: Fire Technote 2006-07R, Fire watch for fire alarm work
- Office of the Fire Marshal: Fire Technote 2006-08R, Fire watch for sprinkler work
- Office of the Fire Marshal: Bulletin 2001-16, Hot work
- Office of the Fire Marshal: Publications