OSHA 10 General Industry Practice Test 2026: Practice test 2
Practice test 2 of 3 for the OSHA 10 General Industry Practice Test: 25 more questions with answers and explanations.
-
Question 1 of 25
Show answer
Answer: B. 28 inches
1910.36 says exit access must be at least 28 inches wide at all points so people can move through quickly.
-
Question 2 of 25
Show answer
Answer: C. Without keys, tools or special knowledge
1910.36 says employees must be able to open exit doors from the inside at any time without keys, tools or special knowledge.
-
Question 3 of 25
Show answer
Answer: D. Outward, in the direction of exit travel
1910.36 requires side-hinged doors to swing out in the direction of exit travel when the room holds more than 50 people or is a high-hazard area.
-
Question 4 of 25
Show answer
Answer: D. At least 6 inches
1910.37 says the word 'Exit' must be in letters at least 6 inches high, with strokes at least three-fourths of an inch wide.
-
Question 5 of 25
Show answer
Answer: D. Mark it 'Not an Exit' or with its real use, such as 'Closet'
1910.37 says doors or passages that could be mistaken for exits must be marked 'Not an Exit' or with their actual use.
-
Question 6 of 25
Show answer
Answer: A. No, nothing may be stored in an exit route, even for a short time
1910.37 says exit routes must be kept free of obstructions and nothing may be placed in them, even temporarily.
-
Question 7 of 25
Show answer
Answer: A. It may communicate the plan orally
1910.38 lets employers with 10 or fewer employees communicate the emergency action plan orally instead of in writing.
-
Question 8 of 25
Show answer
Answer: C. How all employees will be accounted for after an evacuation
1910.38 lists procedures to account for all employees after evacuation as one of the minimum parts of an emergency action plan.
-
Question 9 of 25
Show answer
Answer: B. At first assignment, when the worker's duties under the plan change, and when the plan changes
1910.38 requires the plan to be reviewed with each employee at these three times so everyone knows what to do.
-
Question 10 of 25
Show answer
Answer: B. The main fire hazards and how ignition sources are controlled
1910.39 says a fire prevention plan must list the major fire hazards, ignition sources and their controls, and the fire protection equipment needed.
-
Question 11 of 25
Show answer
Answer: C. At least 30 inches, or the width of the equipment if that is greater
1910.303 requires working space at least as wide as the equipment or 30 inches, whichever is greater.
-
Question 12 of 25
Show answer
Answer: B. No, the required working space may not be used for storage
1910.303 says the working space around electric equipment must not be used for storage, so workers can reach the equipment safely.
-
Question 13 of 25
Show answer
Answer: A. 50 volts
1910.303 says live parts of electric equipment operating at 50 volts or more must be guarded, for example by an enclosure or by elevation.
-
Question 14 of 25
Show answer
Answer: C. De-energize the parts, unless that would add hazards or is not feasible
1910.333 says live parts must be de-energized before work unless the employer shows that doing so adds hazards or is not feasible.
-
Question 15 of 25
Show answer
Answer: D. Only qualified persons
1910.333 allows only qualified persons, trained in special precautions and using proper protective equipment and insulated tools, to work on energized parts.
-
Question 16 of 25
Show answer
Answer: D. Not wear them, unless they are made nonconductive
1910.333 says conductive items such as rings, watch bands and necklaces must not be worn near exposed energized parts unless they are rendered nonconductive.
-
Question 17 of 25
Show answer
Answer: A. Before use on any shift
1910.334 says portable cord-and-plug equipment and extension cords must be visually inspected for damage before use on any shift.
-
Question 18 of 25
Show answer
Answer: A. Never use the cord to raise or lower the tool
1910.334 says cords must not be used to raise or lower equipment, must not be stapled, and the ground connection must not be defeated.
-
Question 19 of 25
Show answer
Answer: D. Someone must determine that it is safe to re-energize the circuit
1910.334 says a circuit may not be manually re-energized after a protective device trips until it is found safe, and repeated resetting is banned.
-
Question 20 of 25
Show answer
Answer: C. It conducts electricity and could create a contact hazard
1910.333 restricts conductive cleaning materials such as steel wool near energized parts because they can cause electrical contact.
-
Question 21 of 25
Show answer
Answer: A. Assess the workplace for hazards that call for PPE
1910.132 requires the employer to assess the workplace for hazards and then select PPE that protects against them.
-
Question 22 of 25
Show answer
Answer: D. The workplace evaluated, the person certifying, and the date of the assessment
1910.132 says the written certification names the workplace evaluated, the person certifying it and the assessment date.
-
Question 23 of 25
Show answer
Answer: A. How to put on, take off, adjust and wear the PPE
1910.132 says workers must learn when PPE is needed, what PPE is needed, how to wear it, its limits, and its care and useful life.
-
Question 24 of 25
Show answer
Answer: C. That they understand the training and can use the PPE properly
1910.132 requires each employee to demonstrate understanding of the training and the ability to use PPE properly before doing the work.
-
Question 25 of 25
Show answer
Answer: B. When changes make training out of date, or a worker's use of PPE shows gaps
1910.132 requires retraining when workplace or PPE changes make training obsolete, or when a worker's knowledge or use of PPE is inadequate.
Keyboard: 1–4 to answer, Enter for the next question.
The real test: No public OSHA exam bank. The authorized trainer or online provider runs the course and issues the DOL card.