Nova Scotia Fire Watch Course 2026
This course is for security guards in Nova Scotia who may be posted on a fire watch when a fire alarm or sprinkler system is out of service. It covers the Fire Safety Act, the Fire Code in force since April 2025, Nova Scotia's own rule for impaired systems, chief fire wardens, and safe patrol and response.
En bref
Ce cours gratuit comprend environ 30 minutes de leçons et un test de 25 questions. Obtenez 80 % ou plus pour télécharger une attestation de réussite (privée, non accréditée). Vérifié à partir des sources officielles le 12 octobre 2026.
Ce que vous allez apprendre
- Name the fire law and fire code in force in Nova Scotia and who enforces them
- Apply Nova Scotia's 2-hour rule for shut-down fire protection systems
- Explain the extra rules for alarm and sprinkler shutdowns
- Describe the chief fire warden's role in Nova Scotia buildings
- Patrol, keep an honest log and avoid Fire Safety Act offences
- Respond safely if you find fire or smoke
Obtenez 80 % ou plus pour télécharger votre certificat.
-
Question 1 sur 25
Voir la réponse
Réponse: C. The 2020 National Fire Code, with Nova Scotia changes
Nova Scotia adopted the 2020 National Fire Code starting April 1, 2025. The Fire Safety Regulations adopt it, with Nova Scotia changes, as the Fire Code.
-
Question 2 sur 25
Voir la réponse
Réponse: C. The Fire Safety Act
The Fire Safety Regulations adopt the National Fire Code as the Fire Code under subsection 15(2) of the Fire Safety Act.
-
Question 3 sur 25
Voir la réponse
Réponse: A. The Fire Marshal
Section 13 of the Fire Safety Act lets the Fire Marshal enforce the Act, the regulations and the Fire Code.
-
Question 4 sur 25
Voir la réponse
Réponse: B. Each municipality
Section 19 of the Fire Safety Act requires each municipality to set up a fire safety inspection system and appoint a municipal fire inspector.
-
Question 5 sur 25
Voir la réponse
Réponse: D. Take every reasonable precaution for fire safety
Section 17 says every owner and person must take every precaution that is reasonable in the circumstances to achieve fire safety.
-
Question 6 sur 25
Voir la réponse
Réponse: A. 2 hours
Section 33 of the Fire Safety Regulations changes Article 6.1.1.4 so the rule applies when a fire protection system or any part of it is shut down or inoperative for more than 2 hours.
-
Question 7 sur 25
Voir la réponse
Réponse: B. Notify the fire department and provide trained patrols
Under section 33 of the Fire Safety Regulations, the owner must notify the fire department and provide a sufficient number of trained people to patrol the building until the system is restored.
-
Question 8 sur 25
Voir la réponse
Réponse: B. Industrial sites that keep their own fire brigade
Section 33 says the notice and patrol rule does not apply to industrial or manufacturing facilities that maintain their own industrial fire brigades.
-
Question 9 sur 25
Voir la réponse
Réponse: B. Procedures to alert occupants if there is a fire
Section 33 requires the owner to develop procedures to notify occupants of a fire or other emergency while the alarm and detection system is shut down or inoperative.
-
Question 10 sur 25
Voir la réponse
Réponse: B. When it is shut down for more than 6 hours
Section 33 of the Fire Safety Regulations requires procedures to protect the building when a sprinkler system is shut down for more than 6 hours.
-
Question 11 sur 25
Voir la réponse
Réponse: D. No; follow the fire department and your post orders
Section 33 requires a sufficient number of trained people to patrol the building but does not set a round time, so the frequency comes from the fire department, the owner and your post orders.
-
Question 12 sur 25
Voir la réponse
Réponse: B. Until the system is restored
Section 33 says the trained people must patrol the building until the system is restored to service.
-
Question 13 sur 25
Voir la réponse
Réponse: D. Within 48 hours
Section 37 of the Fire Safety Act requires the owner to notify the Fire Marshal within 48 hours when a sprinkler or fixed-pipe system discharges, subject to the regulations.
-
Question 14 sur 25
Voir la réponse
Réponse: B. Enter without a warrant and post a fire watch
Section 28 lets fire officials enter without a warrant in an emergency and take steps such as removing people or posting a fire watch.
-
Question 15 sur 25
Voir la réponse
Réponse: B. Peace officer powers under the Criminal Code
Section 11 of the Fire Safety Act gives them the powers of a peace officer under the Criminal Code while acting under the Act.
-
Question 16 sur 25
Voir la réponse
Réponse: A. An offence
Section 44 of the Fire Safety Act makes it an offence to tamper with a device intended to enable escape from a fire. Report it right away so it can be fixed.
-
Question 17 sur 25
Voir la réponse
Réponse: D. An offence
Section 44 of the Fire Safety Act makes it an offence to give a fire official information you know, or ought to know, is false or misleading.
-
Question 18 sur 25
Voir la réponse
Réponse: B. A concert hall with an occupant load over 200
Nova Scotia's Section 2.16 requires a chief fire warden in an assembly occupancy, such as a concert hall, with an occupant load over 200. School, college and university assembly occupancies are not included.
-
Question 19 sur 25
Voir la réponse
Réponse: D. At least every 6 months
Article 2.16.1.2, added by the Fire Safety Regulations, requires the chief fire warden to inspect at least every 6 months and give the owner a written report.
-
Question 20 sur 25
Voir la réponse
Réponse: C. 7 years
Nova Scotia's Article 2.16.1.2 requires the owner to keep each report for 7 years and show it to a fire official on request.
-
Question 21 sur 25
Voir la réponse
Réponse: A. Right after you finish the round
Fire departments ask fire watch staff to record each round as it is completed, with the time and their initials or signature.
-
Question 22 sur 25
Voir la réponse
Réponse: C. Warn the occupants with your air horn
When the alarm is out, the fire watch is the alarm. Warn occupants right away, then call 911 from a safe place.
-
Question 23 sur 25
Voir la réponse
Réponse: A. From a safe area away from the fire
Call 911 from a safe area so smoke or flames cannot trap you while you speak with the dispatcher.
-
Question 24 sur 25
Voir la réponse
Réponse: D. If it is small, safe and they are trained
Fire watch duties allow fighting a fire only when it is safe. If not, close the door, leave and let firefighters handle it.
-
Question 25 sur 25
Voir la réponse
Réponse: D. An air horn or whistle to warn occupants
Fire watch staff carry a way to warn people, such as an air horn or whistle, along with a radio or phone, flashlight, keys and the log.
Clavier : 1–4 pour répondre, Entrée pour la question suivante.
À savoir avant l’examen
- Since April 1, 2025, Nova Scotia's Fire Code is the National Fire Code of Canada 2020 with Nova Scotia changes, adopted under the Fire Safety Act.
- If a fire protection system is shut down or not working for more than 2 hours, the owner must notify the fire department and provide enough trained people to patrol the building.
- When a sprinkler system is shut down for more than 6 hours, the owner must have procedures to protect the building.
- An owner must notify the Fire Marshal within 48 hours when a sprinkler system discharges.
- Some Nova Scotia buildings need a chief fire warden who inspects at least every 6 months. The owner keeps the reports for 7 years.
Questions fréquentes
When is a fire watch needed in Nova Scotia?
When a fire protection system, or part of it, is shut down or not working for more than 2 hours, the owner must notify the fire department and provide trained people to patrol the building until the system is restored. A fire official may also post a fire watch in an emergency.
How often do I patrol on a Nova Scotia fire watch?
The provincial rule does not set a fixed number of minutes. Follow the fire department's direction, the owner's procedures and your post orders, and cover every affected area on each round.
Who enforces fire safety in Nova Scotia?
The Fire Marshal may enforce the Fire Safety Act, its regulations and the Fire Code. Each municipality must also run a fire inspection system with a municipal fire inspector.
Is hot work covered by these lessons?
Only briefly. Hot work rules are in the Fire Code and your site's hot work permit. Follow the permit and your supervisor's direction for any fire watch during and after welding or cutting.
L’attestation est-elle accréditée ou reconnue officiellement ?
Non. C’est une attestation de réussite privée, uniquement pour vos connaissances. Elle n’est reconnue, accréditée ni approuvée par aucun gouvernement, organisme de délivrance des permis, autorité de réglementation ou établissement d’enseignement, et elle ne remplace aucun permis, aucune certification ni aucune formation exigés par la loi.