Saskatchewan Fire Watch Course 2026
This course is for security guards in Saskatchewan who may be posted on a fire watch while a fire alarm or sprinkler system is out of service, or during hot work. It covers The Fire Safety Act, the fire code in force, who enforces it, local rules from Regina, fire safety plans and what to do if you find fire.
Respuesta rápida
Este curso gratuito tiene unos 35 minutos de lecciones y un test de 25 preguntas. Con un 80 % o más puedes descargar un certificado de finalización (privado, no acreditado). Contrastado con fuentes oficiales el 12 de octubre de 2026.
Qué aprenderás
- Name the fire law and fire code that apply in Saskatchewan
- Explain the roles of the fire commissioner and local assistants
- Describe when a fire watch is needed and who must be told
- Patrol and keep an accurate fire watch log
- Use the building fire safety plan and respond to a fire
- Avoid the offences listed in The Fire Safety Act
Obtén un 80 % o más para descargar tu certificado.
-
Pregunta 1 de 25
Ver respuesta
Respuesta: D. The Fire Safety Act
The Fire Safety Act (S.S. 2015, c. F-15.11) is Saskatchewan's law respecting fire safety, fire prevention and emergency response services.
-
Pregunta 2 de 25
Ver respuesta
Respuesta: C. The 2020 edition, with Saskatchewan amendments
Section 3 of The Fire Safety Regulations adopts the 2020 National Fire Code of Canada, subject to the amendments in Appendix A.
-
Pregunta 3 de 25
Ver respuesta
Respuesta: A. The Saskatchewan Public Safety Agency (SPSA)
The Act lets the minister appoint an SPSA employee as fire commissioner.
-
Pregunta 4 de 25
Ver respuesta
Respuesta: A. The fire chief or acting fire chief
Section 2 defines the local assistant, for a municipality with a fire department, as the fire chief or acting fire chief.
-
Pregunta 5 de 25
Ver respuesta
Respuesta: B. Administer and enforce the Act in their area
Section 15(1) says every local assistant administers and enforces the Act within their jurisdiction.
-
Pregunta 6 de 25
Ver respuesta
Respuesta: D. A licensed security guard
The regulations read "authority having jurisdiction" as the fire commissioner, a provincial inspector or a local assistant, depending on the case.
-
Pregunta 7 de 25
Ver respuesta
Respuesta: C. Tampering with smoke detectors or sprinklers
Section 42(1)(a) bans tampering with exits, exit signs, emergency lighting, extinguishers, sprinklers, detection devices and fire alarm systems.
-
Pregunta 8 de 25
Ver respuesta
Respuesta: D. $25,000, plus up to $5,000 a day for a continuing offence
Section 42(3) sets a fine of up to $25,000 for an individual, plus up to $5,000 for each day an offence continues.
-
Pregunta 9 de 25
Ver respuesta
Respuesta: C. Obstruct or hinder the inspector
Section 42(1)(c) makes it an offence to obstruct or hinder a fire inspector or a member of a fire department acting under the Act.
-
Pregunta 10 de 25
Ver respuesta
Respuesta: C. A knowingly false or misleading statement
Section 42(1)(e) makes it an offence to knowingly make a false or misleading statement to a fire inspector or fire department member.
-
Pregunta 11 de 25
Ver respuesta
Respuesta: C. To make sure the premises meets fire safety law
Section 29(1) makes the owner responsible for having the premises built, altered and maintained under the Act, the regulations, any orders and local bylaws.
-
Pregunta 12 de 25
Ver respuesta
Respuesta: B. Hourly fire watch patrols, started immediately
Regina's bulletin says that whenever a fire alarm system is out of service, hourly fire watch patrols must start immediately.
-
Pregunta 13 de 25
Ver respuesta
Respuesta: A. The occupants and the fire department
Regina's bulletin says occupants and the fire department must be told when systems go out of service and when they are back.
-
Pregunta 14 de 25
Ver respuesta
Respuesta: D. Call 911, even if the alarm is monitored
Regina's bulletin tells staff to call 911 even if the fire alarm system is monitored.
-
Pregunta 15 de 25
Ver respuesta
Respuesta: C. Keep the remaining parts working where possible
Regina's bulletin says that in a partial impairment, the parts still working should stay in service where possible.
-
Pregunta 16 de 25
Ver respuesta
Respuesta: C. Prominently, on each floor area
At least one copy of the fire emergency procedures must be prominently posted on each floor area.
-
Pregunta 17 de 25
Ver respuesta
Respuesta: C. At least every 12 months
Regina's bulletin says the fire safety plan must be reviewed at least every 12 months.
-
Pregunta 18 de 25
Ver respuesta
Respuesta: C. Two years
Regina's bulletin says test and corrective-measure records must be kept for two years under the National Fire Code.
-
Pregunta 19 de 25
Ver respuesta
Respuesta: C. At intervals of not more than one month
The Fire Safety Regulations amend the code so these buildings hold drills at intervals not greater than one month.
-
Pregunta 20 de 25
Ver respuesta
Respuesta: B. Within three business days
Section 20 of The Fire Safety Act requires the local assistant to investigate every fire and start within three business days.
-
Pregunta 21 de 25
Ver respuesta
Respuesta: D. Work with open flames, or that makes heat or sparks
Regina's bulletin defines hot works as activities that involve open flames or the production of heat or sparks, such as welding and cutting.
-
Pregunta 22 de 25
Ver respuesta
Respuesta: D. The Occupational Health and Safety Regulations, 2020
The Occupational Health and Safety Regulations, 2020 include a hot work section (25-12) in the fire safety part.
-
Pregunta 23 de 25
Ver respuesta
Respuesta: B. Training in the plan's fire emergency procedures
Regina's bulletin says supervisory staff must be trained in the fire emergency procedures before taking on fire safety responsibility.
-
Pregunta 24 de 25
Ver respuesta
Respuesta: A. Report it right away so you can get access
An area you cannot check is an area nobody is watching. Report it so the owner can give you access.
-
Pregunta 25 de 25
Ver respuesta
Respuesta: D. Right after each round
Write each entry as soon as the round ends. Fire protection records may be reviewed by the fire department, so they must be accurate.
Teclado: 1–4 para responder, Intro para la siguiente pregunta.
Qué debes saber antes del examen
- Saskatchewan's Fire Safety Regulations adopt the 2020 National Fire Code of Canada, with Saskatchewan amendments.
- In a municipality with a fire department, the fire chief is the local assistant who administers and enforces The Fire Safety Act.
- Tampering with alarms, detectors, sprinklers, extinguishers or exits is an offence; individuals face fines of up to $25,000.
- Regina's fire safety plan bulletin requires hourly fire watch patrols, started immediately, when a fire alarm system is out of service.
- Occupants and the fire department must be told when fire protection systems go out of service and when they return.
Preguntas frecuentes
Which fire code applies in Saskatchewan?
The 2020 National Fire Code of Canada, adopted by The Fire Safety Regulations with Saskatchewan amendments.
Who enforces fire safety rules in my Saskatchewan city?
The local assistant under The Fire Safety Act, which is the fire chief where the municipality has a fire department. The fire commissioner at the Saskatchewan Public Safety Agency oversees fire safety across the province.
How often do I patrol on a fire watch in Saskatchewan?
It depends on the fire department and your post orders. Regina's fire safety plan bulletin requires hourly patrols when a fire alarm system is out of service.
Should I call 911 if the alarm is monitored?
Yes. Regina's bulletin says to call 911 even if the fire alarm system is monitored.
¿El certificado está acreditado o reconocido oficialmente?
No. Es un certificado de finalización privado, solo para tus conocimientos. No está reconocido, acreditado ni aprobado por ningún gobierno, organismo de licencias, regulador ni institución educativa, y no sustituye ninguna licencia, certificación ni formación exigida por la ley.