EPA Section 608 Certification Practice Test 2026
Technicians who service or dispose of equipment that could release ozone-depleting refrigerant must hold EPA Section 608 certification. You earn it by passing a test given by an EPA-approved certifying organization, and it does not expire. This independent practice follows EPA's Core, Type I, Type II and Type III test topics.
Quick answer
The EPA Section 608 technician certification test (Core, Type I, Type II, Type III and Universal) has 25 core questions plus 25 for each type (Universal: 100). Pass mark: 70 percent on closed-book tests; 84 percent on mail-in Type I tests. It is run by the U.S. Environmental Protection Agency (EPA), Clean Air Act Section 608 and 40 CFR Part 82, Subpart F; tests given by EPA-approved certifying organizations. Practise here for free with 75 questions, each with the answer and an explanation. Checked against official sources on October 22, 2026.
-
Question 1 of 25
Show answer
Answer: B. The stratosphere
EPA explains that the protective ozone layer is in the stratosphere, the layer of the atmosphere above the troposphere where our weather happens.
-
Question 2 of 25
Show answer
Answer: B. Chlorine
When strong UV light breaks down CFCs and HCFCs high in the atmosphere, they release chlorine atoms, and chlorine destroys ozone.
-
Question 3 of 25
Show answer
Answer: D. More than 100,000
EPA explains that one chlorine atom can destroy over 100,000 ozone molecules, which is why even small releases matter.
-
Question 4 of 25
Show answer
Answer: B. CFCs
CFCs have the highest ozone depletion potential of the common refrigerant groups, HCFCs have less, and HFCs contain no chlorine.
-
Question 5 of 25
Show answer
Answer: B. January 1, 2020
EPA states that HCFC-22 was phased out in the United States as of January 1, 2020, under the Clean Air Act phaseout schedule.
-
Question 6 of 25
Show answer
Answer: C. It may still be serviced, and recovered or reclaimed R-22 is legal to use
EPA does not require existing HCFC-22 systems to be replaced, and recovered and reclaimed HCFC-22 is still legal to use for service.
-
Question 7 of 25
Show answer
Answer: D. It is prohibited
Under 40 CFR 82.154, no person servicing or disposing of an appliance may knowingly vent or otherwise release refrigerant into the environment.
-
Question 8 of 25
Show answer
Answer: B. When it happens while the required service and recovery practices are followed
Releases are de minimis only if they occur while the required practices, such as proper recovery with certified equipment, are being followed.
-
Question 9 of 25
Show answer
Answer: B. Nitrogen
The rule lists carbon dioxide, nitrogen and water as exempt substitutes in any application, so releasing them is not a venting violation.
-
Question 10 of 25
Show answer
Answer: B. Remove it from an appliance and store it in an outside container
Recovery means taking refrigerant out of an appliance in any condition and storing it in an external container, without needing to test or process it.
-
Question 11 of 25
Show answer
Answer: B. Clean it for reuse with basic steps such as oil separation and filter-driers
Recycling cleans refrigerant with basic methods such as oil separation and filter-driers for reuse in equipment of the same owner, but it does not meet reclaim purity.
-
Question 12 of 25
Show answer
Answer: B. Reprocess it to the purity in AHRI Standard 700 and verify that purity by testing
Reclaiming means reprocessing recovered refrigerant to at least the AHRI 700 purity standard and verifying it with the standard's test method.
-
Question 13 of 25
Show answer
Answer: A. It must be reclaimed by an EPA-certified reclaimer
EPA says that if recovered refrigerant changes ownership, it must be reclaimed by an EPA-certified refrigerant reclaimer.
-
Question 14 of 25
Show answer
Answer: A. Only EPA-certified technicians, or employers who show proof they employ one
The sales restriction allows sales to certified technicians, or to employers who give written evidence that they employ at least one certified technician.
-
Question 15 of 25
Show answer
Answer: D. Only refrigerant acceptable for motor vehicle air conditioners
EPA says Section 609 technicians may buy only refrigerant for motor vehicle air conditioners, not refrigerant intended for stationary equipment.
-
Question 16 of 25
Show answer
Answer: A. Small cans of MVAC refrigerant with unique fittings and self-sealing valves
Small containers of non-exempt MVAC refrigerant, two pounds or less, with unique fittings and self-sealing valves, are an exception to the sales restriction.
-
Question 17 of 25
Show answer
Answer: C. Anyone whose work could reasonably be expected to open the refrigerant circuit
EPA defines a technician as anyone whose work could reasonably be expected to violate the integrity of the refrigerant circuit, such as attaching hoses.
-
Question 18 of 25
Show answer
Answer: D. When closely and continually supervised by a certified technician
EPA exempts apprentices from certification only while they are closely and continually supervised by a certified technician.
-
Question 19 of 25
Show answer
Answer: B. It does not expire
EPA states that Section 608 technician certification credentials do not expire, although EPA reserves the right to require recertification later.
-
Question 20 of 25
Show answer
Answer: D. Until 3 years after they stop working as a technician
Technicians must keep a copy of their certificate until three years after they are no longer operating as a technician.
-
Question 21 of 25
Show answer
Answer: C. The EPA-approved certifying organization that gave the test
EPA does not issue certification cards; the EPA-approved certifying organization that gave your test provides the card.
-
Question 22 of 25
Show answer
Answer: A. Equipment certified by an EPA-approved testing organization
EPA requires recovery and recycling equipment to be certified by an EPA-approved testing organization. Some equipment made before November 15, 1993 is grandfathered.
-
Question 23 of 25
Show answer
Answer: C. To remove air and moisture from the system
EPA's core topics describe dehydration evacuation as removing air and moisture from the system before it is closed and charged.
-
Question 24 of 25
Show answer
Answer: A. Dry nitrogen
EPA's core topics cover using nitrogen for leak checks, and nitrogen is an exempt substitute that may be released into the air.
-
Question 25 of 25
Show answer
Answer: B. Mixed refrigerant is hard or impossible to reclaim to purity standards
EPA's core topics include avoiding refrigerant mixing during recovery, because a mixture cannot easily be reclaimed and may have to be destroyed.
Keyboard: 1–4 to answer, Enter for the next question.
The real test: 70 percent on closed-book tests; 84 percent on mail-in Type I tests
What to know before the test
- There are four kinds of certification: Type I for small appliances, Type II for high-pressure appliances, Type III for low-pressure appliances, and Universal for all types.
- Each test has 25 core questions plus 25 questions for each type you take. A Universal test has 100 questions: 25 core and 25 for each type.
- The passing score is 70 percent for closed-book Type I, II, III and Universal tests, and 84 percent for Type I tests taken in mail-in format.
- Universal certification needs a proctored core test. Open-book core tests and mail-in Type I tests cannot be used toward Universal.
- Section 608 certification does not expire. EPA does not issue the cards; the approved certifying organization that gave your test does.
- You must keep a copy of your certificate at your place of business until three years after you stop working as a technician.
- Only certified technicians, or employers who show they employ one, may buy refrigerant for stationary equipment, with limited exceptions.
Frequently asked questions
Who needs EPA Section 608 certification?
Anyone who maintains, services, repairs or disposes of stationary refrigeration or air conditioning equipment in a way that could release refrigerant. Apprentices are exempt only while closely and continually supervised by a certified technician.
How many questions are on the EPA 608 test and what is the pass mark?
Each test has a 25-question Core section plus 25 questions for each type you take, so a Universal test has 100. You need 70 percent on closed-book tests, or 84 percent on a mail-in Type I test.
Where do I take the EPA 608 test?
With an EPA-approved certifying organization. EPA keeps a list of approved programs, and some offer remote or online testing. EPA does not give the test itself.
Does EPA 608 certification expire?
No. EPA says Section 608 credentials do not expire. If you lose your card, contact the certifying organization that tested you.
Is this the real EPA test?
No. This is independent practice written from EPA's test topics and the Section 608 regulations. It is not connected to EPA or any certifying organization.
Sources
- EPA: Section 608 technician certification
- EPA: Section 608 technician certification requirements
- EPA: Section 608 test topics
- EPA: Certification programs for Section 608 technicians
- 40 CFR 82.161: Technician certification
- 40 CFR Part 82, Subpart F, Appendix D: Standards for technician certification programs
- 40 CFR 82.156: Proper evacuation of refrigerant from appliances
- 40 CFR 82.157: Appliance maintenance and leak repair
- 40 CFR 82.154: Prohibitions
- EPA: Refrigerant sales restriction
- EPA: Definitions of Section 608 terms
- EPA: Safe disposal requirements