Fire Watch Course for Security Guards 2026

This course is for security guards who may be posted on a fire watch while a fire alarm or sprinkler system is out of service, or during hot work. It covers when a fire watch is needed, patrol rounds, the log, and what to do if you find fire or smoke.

  • Kurs
  • Kanada
  • 25 Fragen
  • Geprüft am 11. Oktober 2026

Kurz und knapp

Dieser kostenlose Kurs hat Lektionen für etwa 30 Minuten und einen Test mit 25 Fragen. Ab 80 % können Sie eine Teilnahmebescheinigung herunterladen (privat, nicht akkreditiert). Am 11. Oktober 2026 mit offiziellen Quellen abgeglichen.

Beginnen Sie mit den LektionenFire Watch Course: Lessons: etwa 30 Minuten Lesezeit. Jede Testfrage wird in den Lektionen behandelt.

Das lernen Sie

  • Explain when a fire watch is needed and why it is temporary
  • Prepare the right equipment and building information
  • Patrol at the required frequency and spot fire hazards
  • Keep an accurate fire watch log
  • Respond safely if you find fire or smoke
  • Apply hot work fire watch rules

Erreichen Sie mindestens 80 %, um Ihr Zertifikat herunterzuladen.

  1. Frage 1 von 25

    When is a fire watch most often needed in a building?
    Antwort anzeigen

    Antwort: D. When a fire alarm or sprinkler system is out of service or impaired

    A fire watch is an alternative safety measure used while a fire protection system, such as the alarm or sprinklers, is shut down or impaired.

  2. Frage 2 von 25

    What kind of measure is a fire watch?
    Antwort anzeigen

    Antwort: C. A short-term measure until the fire protection system is repaired

    Fire departments describe a fire watch as temporary. The owner must still arrange repairs so the system returns to service.

  3. Frage 3 von 25

    Fire codes say that when part of a fire protection system is shut down, what must happen?
    Antwort anzeigen

    Antwort: D. Alternative measures must be taken, such as a fire watch

    Fire codes based on the National Fire Code require alternative measures while a system is shut down. A fire watch is the most common one.

  4. Frage 4 von 25

    Do all Canadian cities use the same rule for when the fire department must be told a system is out of service?
    Antwort anzeigen

    Antwort: C. No, it varies; for example Vancouver uses more than 4 hours and Medicine Hat more than 2 hours

    Notification rules are set locally. Vancouver's order uses 4 hours in 24, while Medicine Hat asks for a call if detection is out more than 2 hours.

  5. Frage 5 von 25

    Besides the fire department, who else should be told when a monitored fire alarm goes out of service?
    Antwort anzeigen

    Antwort: D. The monitoring station that watches the fire alarm

    The central station that monitors the alarm must know when the system is out of service and when it is returned to service.

  6. Frage 6 von 25

    Which item is on the usual equipment list for a fire watch guard?
    Antwort anzeigen

    Antwort: C. An air horn or whistle to alert occupants

    Fire watch staff carry a way to alert people, such as an air horn or whistle, plus a radio or phone, flashlight, keys and the log sheet.

  7. Frage 7 von 25

    Why should a fire watch guard carry keys or access codes for the affected areas?
    Antwort anzeigen

    Antwort: C. So every area can be checked on each round

    A fire watch must cover all affected areas. Without keys or codes, locked rooms would go unchecked.

  8. Frage 8 von 25

    Before you start a fire watch, what should you know about the fire extinguishers?
    Antwort anzeigen

    Antwort: D. Where they are and how to use them

    Fire watch staff need to know where extinguishers are and be trained to use them, in case a small fire can be fought safely.

  9. Frage 9 von 25

    May a fire watch guard take on other duties, such as watching a loading dock, during the watch?
    Antwort anzeigen

    Antwort: C. Usually no; the fire watch should be their only duty unless it is approved

    Fire watch procedures, such as Queen's University's, say watchers must not have other duties unless approved, so the rounds are not missed.

  10. Frage 10 von 25

    Under Vancouver's fire watch order, how often must a non-residential building be patrolled during normal business hours?
    Antwort anzeigen

    Antwort: D. At least every 30 minutes

    Vancouver's order sets 30 minutes in business hours and 60 minutes at other times for non-residential buildings.

  11. Frage 11 von 25

    Under Vancouver's fire watch order, how often must a building with sleeping rooms be patrolled overnight (9 pm to 8 am)?
    Antwort anzeigen

    Antwort: A. At least every 15 minutes

    People who are asleep may not notice a fire, so rounds are more frequent in buildings with sleeping accommodation: every 15 minutes overnight.

  12. Frage 12 von 25

    Windsor and Medicine Hat fire watch duties set which minimum patrol?
    Antwort anzeigen

    Antwort: C. Tour the entire building each hour

    Both documents say fire watch personnel must tour the entire building each hour. Always follow the frequency your fire department or site sets.

  13. Frage 13 von 25

    During each round, what should you check at exit doors and corridors?
    Antwort anzeigen

    Antwort: A. That they open properly and are not blocked

    Exits must stay clear and readily openable on both sides, so people can escape if a fire starts.

  14. Frage 14 von 25

    When should you fill in the fire watch log?
    Antwort anzeigen

    Antwort: B. Right after each round is completed

    Each round is recorded immediately on the log sheet with the time and your initials or signature.

  15. Frage 15 von 25

    Which detail belongs in each fire watch log entry?
    Antwort anzeigen

    Antwort: A. The time of the round, the areas checked, observations and your initials

    Logs record the date, time, area, observations and the watcher's signature or initials, in time order.

  16. Frage 16 von 25

    Vancouver's order asks fire watch staff to record people with a disability who may need help. Why?
    Antwort anzeigen

    Antwort: D. So responders know who needs help to evacuate and where they are

    Knowing the names and locations of people who need help lets staff and firefighters reach them quickly.

  17. Frage 17 von 25

    You smell smoke and see flames on your round. What should you do first?
    Antwort anzeigen

    Antwort: A. Alert the occupants with your air horn or other approved signal

    With the alarm out of service, you are the alarm. Warn occupants right away, then call 911 from a safe place.

  18. Frage 18 von 25

    Where should you call 911 from when you discover a fire on a fire watch?
    Antwort anzeigen

    Antwort: A. From a safe area away from the fire

    Call 911 from a safe area so you are not trapped by smoke or flames while you talk to the dispatcher.

  19. Frage 19 von 25

    When should a fire watch guard try to put out a fire?
    Antwort anzeigen

    Antwort: A. Only if it is small and safe to do so, and they are trained

    Fire watch duties allow fighting a fire only if it is safe. If it is not safe, evacuate and let the fire department handle it.

  20. Frage 20 von 25

    After the building is evacuated, when may people go back inside?
    Antwort anzeigen

    Antwort: A. Only when the fire department says it is safe

    Do not re-enter without the fire department's permission. Wait at a safe spot and guide responders to the scene.

  21. Frage 21 von 25

    In many fire codes, how long must a hot work fire watch continue after welding or cutting is finished?
    Antwort anzeigen

    Antwort: B. At least 60 minutes

    Sparks and hot metal can start a hidden fire after work stops, so the fire watch continues for at least 60 minutes after completion.

  22. Frage 22 von 25

    Winnipeg's hot work rules require a final check of the area how long after the hot work ends?
    Antwort anzeigen

    Antwort: B. 4 hours after completion

    A final inspection 4 hours after hot work helps catch smouldering fires that the fire watch may have missed.

  23. Frage 23 von 25

    During hot work, how close must combustible materials be before they need protection from sparks?
    Antwort anzeigen

    Antwort: D. Within 15 m of the work

    Combustibles within 15 m that cannot be moved must be protected, for example covered or wetted down.

  24. Frage 24 von 25

    What must be in the hot work area during the work?
    Antwort anzeigen

    Antwort: A. At least one portable fire extinguisher

    Hot work rules require at least one portable fire extinguisher in the area, and the fire watch must know how to use it.

  25. Frage 25 von 25

    When can a fire watch be ended?
    Antwort anzeigen

    Antwort: B. After the system is confirmed fully working and the fire department and monitoring station are told

    Cancel the watch only after the alarm and sprinklers are confirmed fully operational, then notify the fire department and any monitoring station.

Was Sie vor der Prüfung wissen sollten

  • Fire codes require alternative measures, such as a fire watch, when part of a fire protection system is shut down.
  • Patrol frequency is set locally. Windsor and Medicine Hat ask for a tour of the entire building every hour.
  • Vancouver requires patrols every 15 minutes overnight in buildings where people sleep.
  • A hot work fire watch continues for at least 60 minutes after the work ends, with a final check 4 hours after.
  • If you find fire, alert occupants, call 911 from a safe area and fight the fire only if it is safe.

Häufig gestellte Fragen

What does a fire watch guard do?

They patrol the affected building on a set schedule, look for fire and hazards, keep a log, and warn occupants and call 911 if they find fire or smoke.

How often do I patrol on a fire watch?

It depends on your fire department and site. Some cities ask for a full tour every hour; Vancouver asks for every 15 to 60 minutes depending on the building and the time of day.

Can I do other tasks during a fire watch?

Usually not. Many procedures say the fire watch should be your only duty unless it is approved, so no rounds are missed.

How long does a fire watch after welding last?

Fire codes such as Manitoba's require it during the hot work and for at least 60 minutes after, with a final inspection 4 hours after the work ends.

Ist die Bescheinigung akkreditiert oder offiziell anerkannt?

Nein. Es ist eine private Teilnahmebescheinigung, nur für Ihr Wissen. Sie ist von keiner Behörde, Zulassungsstelle, Aufsichtsbehörde oder Bildungseinrichtung anerkannt, akkreditiert oder genehmigt und ersetzt keine gesetzlich vorgeschriebene Lizenz, Zertifizierung oder Ausbildung.

Quellen

Ähnliche Tests